Read Sharp ER-A411 / ER-A421 (serv.man3) Service Manual online
SRV MODE
9-1
CHAPTER 9. SRV MODE
1.OUT LINE
This programming chiefly consists of service programming jobs and to perform this programming, it must be entered the SRV-mode by
program reset operation.
Reports on the contents of this programming can be printed.
Purpose
This programming is mainly performed when the ECR is shipped,
installed, or serviced.
[Operation]
1. Enter
1. Enter
SRV-mode
Operator can enter the SRV-mode by program reset operation.
Please refer to "Program resetting" about program reset
operation.
Enter the SRV mode secret code when the MODE menu is
displayed.
[MODE] → xxxxxxxx (SRV mode secret code) → [ENTER]
Programming
Perform the programming following the procedure shown below.
Data entry: (Data) --> ENTER
Exit: TL
See the descriptions of respective programming procedures for
job code and data.
NOTE: Sweden/Netherland/Norway/Germany fiscal
specification
This model supports fiscal specification.
Master
resetting
Master resetting clears the entire memory and resumes initial
values.
Initial values of language can be selected one from following 5
kinds.
1 English
4 Spanish
2 German
5 Swedish
3 French
Master resetting is available in the following two types:
Master
resetting
1:
Clears the entire memory and resumes initial values.
Master
resetting
2:
Clears the entire memory and resumes initial values.
(Master resetting 2 enables the layout of fixed keys in
addition to master resetting 1.)
Master resetting 1 and 2 can be accomplished by using the
following procedures.
1. Master resetting 1
1)
Unplug the AC cord from the wall outlet.
2)
Push [JOURNAL paper feed] key and [1] key.
3)
Plug in the AC cord to the wall outlet during the depression
of above 2 keys.
Enter the secret key operation.
(--> Language selection menu is displayed.)
4)
Push the corresponding number key.
(--> MASTER RESET progress bar is displayed.)
(--> DATE/TIME setting screen is displayed.)
5)
Set current date/time and push [TL] key.
(--> TAX RATE setting screen is displayed.)
6)
Set tax rate and push [TL] key. (REG mode screen is
displayed when [CANCEL] key is pushed.)
(--> REG mode screen is displayed.)
2. Master resetting 2
1)
Unplug the AC cord from the wall outlet.
2)
Push [JOURNAL paper feed] key and [2] key.
3)
Plug in the AC cord to the wall outlet during the depression
of above 2 keys.
Enter the secret key operation.
(--> Language selection menu is displayed.)
4)
Push the corresponding number key.
(--> [ENTER 0 KEY] is displayed.)
5)
Program following keys in this sequence.
(This means that the key first pressed is programmed as the
[0] key, the key pressed second as [1] key ---- and the last
key pressed as the [TL] key.)
To inhibit a particular key, press the [0] key at the point
when that key should be programmed.
Key
0 to 9
00
"." (decimal point)
(X)
SBTL
MODE
Cursor keys
CANCEL
CL
ENTER
TL
Click on the first or last page to see other ER-A411 / ER-A421 (serv.man3) service manuals if exist.