ER-A411, ER-A421 (serv.man3). ER-A411 421 Service and Programming Manual - Sharp ECR Service Manual (repair manual). Page 111

Read Sharp ER-A411 / ER-A421 (serv.man3) Service Manual online

SRV MODE 
9-1 
 
CHAPTER 9. SRV MODE 
1.OUT LINE 
This programming chiefly consists of service programming jobs and to perform this programming, it must be entered the SRV-mode by 
program reset operation. 
Reports on the contents of this programming can be printed. 
 
  Purpose 
This programming is mainly performed when the ECR is shipped, 
installed, or serviced. 
 
  [Operation] 
1. Enter 
SRV-mode 
Operator can enter the SRV-mode by program reset operation. 
Please refer to "Program resetting" about program reset 
operation. 
Enter the SRV mode secret code when the MODE menu is 
displayed. 
 
[MODE]    xxxxxxxx (SRV mode secret code)   [ENTER] 
 
 
  Programming 
Perform the programming following the procedure shown below. 
Data entry: (Data)  -->  ENTER 
Exit: TL 
See the descriptions of respective programming procedures for 
job code and data. 
 
NOTE: Sweden/Netherland/Norway/Germany fiscal 
specification 
This model supports fiscal specification. 
 
 Master 
resetting 
Master resetting clears the entire memory and resumes initial 
values. 
Initial values of language can be selected one from following 5 
kinds. 
1 English  
4 Spanish 
2 German 
5 Swedish 
3 French 
 
Master resetting is available in the following two types: 
 Master 
resetting 
1: 
 
Clears the entire memory and      resumes initial values. 
 Master 
resetting 
2: 
 
Clears the entire memory and resumes initial values. 
(Master resetting 2 enables the layout of fixed keys in 
addition to master resetting 1.) 
Master resetting 1 and 2 can be accomplished by using the 
following procedures. 
 
1.  Master resetting 1 
1) 
Unplug the AC cord from the wall outlet. 
2) 
Push [JOURNAL paper feed] key and [1] key. 
3) 
Plug in the AC cord to the wall outlet during the depression 
of above 2 keys. 
Enter the secret key operation. 
  (--> Language selection menu is displayed.) 
4) 
Push the corresponding number key. 
(--> MASTER RESET progress bar is displayed.) 
(--> DATE/TIME setting screen is displayed.) 
5) 
Set current date/time and push [TL] key. 
(--> TAX RATE setting screen is displayed.) 
6) 
Set tax rate and push [TL] key. (REG mode screen is 
displayed when [CANCEL] key is pushed.) 
(--> REG mode screen is displayed.) 
 
2.  Master resetting 2 
1) 
Unplug the AC cord from the wall outlet. 
2) 
Push [JOURNAL paper feed] key and [2] key. 
3) 
Plug in the AC cord to the wall outlet during the depression 
of above 2 keys. 
Enter the secret key operation. 
  (--> Language selection menu is displayed.) 
4) 
Push the corresponding number key. 
(--> [ENTER 0 KEY] is displayed.) 
5) 
Program following keys in this sequence. 
(This means that the key first pressed is programmed as the 
[0] key, the key pressed second as [1] key ---- and the last 
key pressed as the [TL] key.)   
To inhibit a particular key, press the [0] key at the point 
when that key should be programmed. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Key 
0 to 9 
00 
"." (decimal point) 
(X) 
SBTL 
MODE 
Cursor keys 
CANCEL 
CL 
ENTER 
TL 
Page of 127
Display

Click on the first or last page to see other ER-A411 / ER-A421 (serv.man3) service manuals if exist.