Read Sharp ER-A411 / ER-A421 (serv.man2) Service Manual online
Page 7
New functions
PLU Menu Key
[V1.10]
PLU Menu key: 2 digits (1 – 25) (*)
Item
Text
Range/Detail
Default
Text
TEXT
16 character
(blank)
PLU or Sub-Menu 01 PLU or Sub-Menu
02 PLU or Sub-Menu
01 PLU or Sub-Menu
15 PLU or Sub-Menu
PLU code: 5 digits (1-99999) (**)
or Sub-Menu: 2 digits (1-25)
Max. 15 PLUs and/or Sub_Menus
(*) When the “DEL” key is pressed on table number selection menu, the table is deleted.
(**) The EAN code (6 – 14 digit code) cannot be programmed.
2. Transaction-Log (T-Log) Function
[V1.10]
It is not possible to use the T-LOG and E-Journal function at the same time.
By SRV#987-C selection between both function can be done.
Note:
In / Dutch - / German - / Norwegian - / Swedish Fiscal mode only the E-Journal function can be used.
The above SRV parameter is fixed to “0” (E-Journal).
Operator display indication
Indication of used T-LOG memory consumption is added to the information area.
80% of capacity of T-Log memory have been used.
90% of capacity of T-Log memory have been used.
95% of capacity of T-Log memory have been used.
Transaction and operation recording
Mode
T-Log file recording
REG mode
Manager mode
Void mode
Training mode *1
Transaction details
X/Z mode
Kind of report / no report details
PGM mode
Only PGM mode executing / no PGM Job and details
Off mode
SD card mode
iSDC mode
SRV mode
Online (including RJE X/Z)
No data
*1 It is done if SRV#986-D “EJ / T-LOG recording in Training mode” is set to YES.
Click on the first or last page to see other ER-A411 / ER-A421 (serv.man2) service manuals if exist.