ER-A411, ER-A421 (serv.man2). ERA411 421 Programming, Operation Manual updated to include ROM V1.33 - Sharp ECR Service Manual (repair manual). Page 15

Read Sharp ER-A411 / ER-A421 (serv.man2) Service Manual online

 
 
Page 15 
 
 
 
Changes / Improvements / Corrections 
C 3   >>> Changes / Improvements / Corrections since V1.30 <<< 
 
C 3.1  Compulsory EFT key not any longer active 
In case of a power failure or unplug from power supply the before defined compulsory EFT key (CH1 – 5 / 
CR1 – 9) are not any longer active. 
This is corrected in this version. 
 
C 3.2  With Point Transaction custom firmware (Easycard protocol) signature receipt is not printed. 
In case of Finland the Easycard protocol used together the Yomani EFT terminal causes that the signature 
receipt is not issued at ECR side. 
This is corrected in this version. 
 
C 3.3  Recommended Panasonic and Toshiba SD-card types are not adopted 
 
Since the following SD card types are used or are going to use a different component (NAND Flash) causes that 
these cards do not function any longer. 
 
Panasonic: From July 2014 production 
RP-SDWA04GJK (4GB) 
             
RP-SDWA08GJK (8GB) 
             
RP-SDWA16GJK (16GB) 
             
RP-SDWA32GJK (32GB) 
 
Toshiba:    From December 2014 production 
SD-BU016G (16GB) 
             
SD-BU032G (32GB) 
C 4  >>> Changes / Improvements / Corrections since V1.31 <<< 
C 4.1 ECR lock after plug-in / out in Sleep or Off mode 
When plug off the ECR during keystroke entry, in OFF mode or during SLEEP mode and plug in again 
the ECR will not work probably.  
 
For the ER-A411/A421 the probability of this issue is round about 1/2000.  
When this phenomenon occurs a PROGRAM RESET is required. 
Fortunately it has no influence to memory and the ECR can be used continuously. 
This is corrected in this version. 
C 5  >>> Changes / Improvements / Corrections since V1.32 <<< 
 
C 5.1 Sometimes illegal PLU link record occurs  
If a PLU is continuously deleted more than 3 times causes: 
-  If a PLU text is changed also the text of a other PLU is changed 
-  Both PLUs turnover are updated in one totalizer 
 
Example: 
Master reset 
Delete PLU11 / Delete PLU12 / Delete PLU13 / Delete PLU14 / Delete PLU15 / Delete PLU16 /Delete PLU18 / 
Add PLU30 
This is corrected in this version. 
 
 
 