Read Sharp ER-A411 / ER-A421 (serv.man19) Driver / Update online
CONFIDENTIAL
ER-A411/A421
European version
PCLINK Specifications
(Subject to change for improvement)
Date of issue
: Aug. 30, 2013
SHARP CORPORATION
BUSINESS SOLUTIONS PROMOTION DIVISION
SYSTEM EQUIPMENT UNIT
ER-A411/A421 PCLINK
SHARP Confidential
1
1
OUTLINE ............................................................................................................................................ 2
2
SYSTEM REQUIREMENTS ................................................................................................................ 2
2.1
O
PERATING
S
YSTEM
........................................................................................................................ 2
2.2
R
UNTIME
E
NVIRONMENT
.................................................................................................................. 2
3
SYSTEM CONFIGURATION ............................................................................................................... 2
4
FUNCTIONS ....................................................................................................................................... 3
4.1
S
ETTING AND COMMUNICATION FUNCTION
.......................................................................................... 3
4.2
P
LURAL DATA SET MANAGEMENT
. ....................................................................................................... 4
4.3
M
ULTI
-
L
ANGUAGE SUPPORT
............................................................................................................. 4
4.4
C
HARACTER EXCHANGE SUPPORT
. .................................................................................................... 4
5
INSTALLATION................................................................................................................................... 4
6
EACH FUNCTIONS ............................................................................................................................ 5
6.1
S
TART UP
....................................................................................................................................... 5
6.2
T
ERMINATION
.................................................................................................................................. 5
6.3
T
ITLE BAR
....................................................................................................................................... 6
6.4
M
ENU BAR
...................................................................................................................................... 6
6.5
F
ILE
............................................................................................................................................... 7
6.6
E
XEC
........................................................................................................................................... 12
6.7
R
ECORD
....................................................................................................................................... 14
6.8
A
BOUT
......................................................................................................................................... 15
6.9
D
EPARTMENT PROGRAMMING
.......................................................................................................... 16
6.10
PLU
PROGRAMMING
................................................................................................................... 21
6.11
PLU/EAN
PROGRAMMING
........................................................................................................... 24
6.12
LOGO
PROGRAMMING
(T
HERMAL
L
OGO
)...................................................................................... 29
6.13
LOGO
TEXT PROGRAMMING
........................................................................................................ 31
6.14
VAT
ID
PROGRAMMING
............................................................................................................... 35
6.15
ALL
RAM
B
ACKUP
/R
ESTORE
...................................................................................................... 37
6.16
VAT/TAX
RATE PROGRAMMING
.................................................................................................... 33
7
INTERNAL DATA HANDLING........................................................................................................... 39
8
DISPLAY........................................................................................................................................... 42
8.1
D
ATA TRANSMISSION
...................................................................................................................... 42
8.2
S
TATUS INDICATION
........................................................................................................................ 42
9
AVAILABLE CHARACTERS............................................................................................................. 43
10
MESSAGES...................................................................................................................................... 44
11
RESTRICTIONS................................................................................................................................ 54
ER-A411/A421 PCLINK
SHARP Confidential
2
1 Outline
This software edit and keep the various preset data for ECR (ER-A411, ER-A421).
The data are exchanged to ECR via RS232 or SD Card.
2 System Requirements
2.1 Operating System
Windows XP Professional SP3 (32-bit)
Windows Vista Ultimate SP2 (32-bit
/ 64-bit
)
Windows 7 Ultimate SP1 (32-bit / 64-bit)
Windows 8 Pro (32-bit / 64-bit)
Windows 8 Pro (32-bit / 64-bit)
2.2 Runtime Environment
.NET Framework 3.5 is necessary.
3 System Configuration
This software is working under following system configuration.
In case of RS-232, it can read and write ECR data directly by cable connection between ECR and PC.
In case of SD Card, the data which can be read and write on ECR are stored on SD Card.
The data is exchanged by the SD Card function of ECR.
The software provide above communication function and data read/write function.
In case of SD Card, the data which can be read and write on ECR are stored on SD Card.
The data is exchanged by the SD Card function of ECR.
The software provide above communication function and data read/write function.
PC
ECR
RS-232
SD CARD
ER-A411/A421 PCLINK
SHARP Confidential
3
4 Functions
This software have following functions.
4.1 Setting and communication function
207
217
307
DATA
FUNCTION
DIRECTION
MEDIA
FILE NAME
DEPT
DATA ENTRY
(Department)
UPLOAD
ECR -> PC
RS-232
DOWNLOAD
PC -> ECR
RS-232
IMPORT
SD -> PC
SD CARD
DEPTDT
EXPORT
PC -> SD
SD CARD
DEPTDT
x
PLU
DATA ENTRY
UPLOAD
ECR -> PC
RS-232
DOWNLOAD
PC -> ECR
RS-232
IMPORT
SD -> PC
SD CARD
PLUDT
EXPORT
PC -> SD
SD CARD
PLUDT
x
x
PLU/EAN
DATA ENTRY
UPLOAD
ECR -> PC
RS-232
DOWNLOAD
PC -> ECR
RS-232
IMPORT
SD -> PC
SD CARD
PLUDT
EXPORT
PC -> SD
SD CARD
PLUDT
LOGO TEXT
DATA ENTRY
UPLOAD
ECR -> PC
RS-232
DOWNLOAD
PC -> ECR
RS-232
IMPORT
SD CARD->PC
SD CARD
LOGODT
EXPORT
PC -> SD CARD SD CARD
LOGODT
TAX
DATA ENTRY
(VAT/TAX rate)
UPLOAD
ECR -> PC
RS-232
DOWNLOAD
PC -> ECR
RS-232
IMPORT
SD -> PC
SD CARD
TAXTB
EXPORT
PC -> SD
SD CARD
TAXTB
VAT ID
DATA ENTRY
UPLOAD
ECR -> PC
RS-232
DOWNLOAD
PC -> ECR
RS-232
LOGO
DOWNLOAD
PC -> ECR
RS-232
(Graphic logo)
EXPORT
PC -> SD
SD CARD
TMLOG1TB
ALL RAM
UPLOAD
ECR -> PC
RS-232
DOWNLOAD
PC -> ECR
RS-232
DATA
The data of setting (All RAM means the dead copy of ECR RAM. (Except internal memory)
FUNCTION
The following data can be controlled.
Function
DATA ENTRY
Add, delete, edit, store, read the data.
Please refer Data Control Function.
Please refer Data Control Function.
UPLOAD
Receive the data from ECR.
DOWNLOAD
Send the data to ECR.
IMPORT
Read the data from SD CARD.
EXPORT
Write the data to SD CARD.
DIRECTION
The direction of data movement.
MEDIA