ER-A410, ER-A420 (serv.man4). ERA410 420 Programming Manual - Sharp ECR Service Manual (repair manual). Page 49

Read Sharp ER-A410 / ER-A420 (serv.man4) Service Manual online

ER-A410/ER-A420
OP X/Z, X1/Z1,X2/Z2 MODE
3 – 3
*
8 The stacked report function enables different reports to be printed
successively with a single reporting operation.
The programming for the stacked reports can be accomplished by
performing the following key operation in the PGM2 mode.
Stacked reports can be printed by performing the following key
operation in the X1/Z1 and X2/Z2 modes.
If the job code of a report that cannot be involved in stacked reports
is programmed,  it is ignored (that report is not printed).
Also, if stacked reports include any other reports for which no Z
reports can be taken, the Z reports of them are ignored and not
printed.
A maximum of 15 different reports can be printed successively with
a single reporting operation.
Those 15 reports can include those reports that are identical in
code number. In this case, however, if any data changes due to the
printing of the previous report, the changed data is printed on the
following report.
For example:
*
9 Reading display only.
The displayed amount can be cleared by [CL] key.
*
10 To read respective contents, it is necessary to follow the proce-
dure below.
[Action]
Individual counters for the following Z reports are incremented when
those reports are printed.
1) General daily total report (Z1)
2) General periodic total report (Z2)
3) Hourly report (Z1)
4) Daily net total report (Z2)
5) PLU report (Z1/Z2)
6) Individual Cashier and All Cashier report (Z1/Z2)
7) Individual Clerk and All Clerk report (Z1/Z2)
[Additional function]
(1) Secret code entry
When printing reports in the X1/Z1 mode and X2/Z2 mode, a secret
code must be entered prior to performing key operations to take
reports.
The secret code can be entered following the procedure shown
below.
(2) Overflow mark
If the amount or quantity in any totalizer other than GT to be printed
on X or Z reports exceeds a programmed limit, the indication mark
(overflow mark) is printed for the totalizer concerned.
The overflow mark may be printed even if a totalizer does not reach
the maximum amount. This occurs, for example, when the amount
or quantity in the totalizer gets smaller than the maximum amount
due to the entry of a negative amount after the overflowing of the
totalizer. This means that when the totalizer overflows once, the
overflow mark (for example, “!!”) is printed.
(3) MODE TITLE
Each report is printed MODE TITLE at a header of report.
There are follows.
(4) Report cancel function
All report printing can be able to stopped.
It can be cancelled by turned the mode switch to MGR position
while the data is printed. (In this case, the contents of memory are
not cleared.)
<Print sample of Report cancel>
Consecutive number: The counter is incremented by one.
Z report:
Data is reset to zero.
2620
XX
JOB No.
START CODE
END CODE
SSSSSS
ST
EEEEEE
TL
ALL DELETE
NEXT JOB
NO RANGE
x90
TL
Reading
Resetting
KEY
CL
(Display amount)
(Display initialize)
JOB#
EURO STATUS
TL
Current Status Reading
Status Change Excuting
COUNTER: Max. 5 (-99999~+99999)
Q’TY:
Max. 7 (-9999999~+9999999)
AMOUNT:
Max. 9 (-999999999~+999999999)
OPX report
#041  
*
OPX
*
OPZ report
#041  
*
OPZ
*
X1 report
#141  
*
X   1
*
Z1 report
#141  
*
Z    1
*
X2 report
#241  
*
X   2
*
Z2 report
#241  
*
Z    2
*
:
:
*
*
*
*
*
*
 
1
 the report cancel symbol
123456789012345678901234
XXX
Secret code
TL
TL
Page of 53
Display

Click on the first or last page to see other ER-A410 / ER-A420 (serv.man4) service manuals if exist.