Read Sharp ER-A220 Service Manual online
[JOB#32] MRS=05
RS-232C function
NK = AB
A :
Function
A
RAM data download and
upload
upload
0
★
Print data send
1
B :
RS-232C baud rate
B
2400 bps
3
★
4800 bps
4
9600 bps
5
19200 bps
6
[JOB#33] MRS=002013
RS-232C programming
NK = XXXYYY
XXX :
Start code
XXX
000-255
000-255
YYY :
End code
YYY
000-255
000-255
[JOB#35] MRS=007
RS-232C time out
NK = XXX
XXX :
Time out time
XXX
1-127 sec.
001-127
[JOB#36] MRS=000
RS-232C print data function
NK = ABC
A :
Sending of DR signal
A
Yes
0
★
No
1
B :
Sending of CS signal
B
Yes
0
★
No
1
C :
Sending of all print data
C
Disable
0
★
Enable
1
[JOB#50] MRS=50
Thermal printer desity control
NK = XX
XX :
Thermal printer desity control
XX
70 % for standard
00
100 % (Standard dendity)
50
★
130 % for standard
99
[JOB#61] MRS=00100112
Other programming -1
NK = ABCDEFGH
A :
Number of department
A
15
0
★
30
1
B : Not used (Fixed at "0")
C :
Programming of Minus dept. /
PLU
PLU
C
Disable
0
Enable
1
★
D :
Fractional treatment
D
Round off (4-down,5-up)
0
★
Raising to unit
1
Disregarding
2
E :
00 key or 000 key selection for
00 key position
00 key position
E
00 key
0
★
000 key
1
F :
Time format
F
12 H
0
24 H
1
★
G :
Date format
G
M-D-Y
0
D-M-Y
1
★
Y-M-D
2
H :
TAB
H
0
0
0.0
1
0.00
2
★
0.000
3
Click on the first or last page to see other ER-A220 service manuals if exist.