ER-A160, ER-A183. Faulty power to motor drawer, change of IC9 - Sharp ECR Technical Bulletin (repair manual). Page 3

Read Sharp ER-A160 / ER-A183 Technical Bulletin online

3/4
Cut-in date: The action has been carried out from November 2001 production.
5.Others:
1) The change of the power supply IC should be made with only IC9 of ER-A160/180.
2) For IC14, VHIPQ1CG2032F is used as before.
6.Parts Action:
Current parts
New parts
Ref.
No.
Model
name
Version P/G No.
Parts code
Parts code
Price
rank
Parts name
Effective
time
Inter-
change-
ability
Note
1
IC9
VHIPQ1CG2032F
VHI2576TVAD-1
IC9
6
  
2
R52
VRD-RC2EY101J
---
Resistance
---
  
3
ER-A160
ER-A180
All
Q29
VS2SC3198-/-1
---
AY
Transistor
2001/11
---
  
<Interchange>
1. Interchangeable.
4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of
related parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.