(1) Using desoldering braid, remove the solder from the foil of
each pin of the flat pack-IC on the CBA so you can install
a replacement flat pack-IC more easily.
(2) The “ ” mark on the flat pack-IC indicates pin 1. (See Fig.
S-1-7.) Be sure this mark matches the 1 on the PCB when
positioning for installation. Then presolder the four corners
of the flat  pack-IC. (See Fig. S-1-8.)
(3) Solder all pins of the flat pack-IC. Be sure that none of the
pins have solder bridges.
Example :
Pin 1 of the Flat Pack-IC
is indicated by a " 
  
 " mark.
Fig. S-1-7
Presolder
CBA
Flat Pack-IC
Fig. S-1-8
Instructions for Handling Semi-conductors
Electrostatic breakdown of the semi-conductors may occur
due to a potential difference caused by electrostatic charge
during unpacking or repair work.
1. Ground for Human Body
Be sure to wear a grounding band (1 Mohm) that is properly
grounded to remove any static electricity that may be charged
on the body.
2. Ground for Workbench
Be sure to place a conductive sheet or copper plate with proper
grounding (1 Mohm) on the workbench or other surface, where
the semi-conductors are to be placed. Because the static
electricity charge on clothing will not escape through the body
grounding band, be careful to avoid contacting semi-conductors
with your clothing.
CBA
< Incorrect >
CBA
Grounding Band
Conductive Sheet or
Copper Plate
< Correct >
1Mohm
1Mohm