DV-SL10H (serv.man11). Schematic diagrams CBA's and test points - Sharp DVD Service Manual (repair manual). Page 7

Read Sharp DV-SL10H (serv.man11) Service Manual online

AV 1/3 Schematic Diagram
1-10-11
1-10-12
E5752SCAV1
NOTE :
The voltage for parts in hot circuit is measured
using hot GND as a common terminal.
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
REPLACE ONLY WITH THE SAME TYPE FUSE.
Page of 14
Display