1-5-1
E9B30PFS
How to Enter the Service Mode
About Optical Sensors
Caution:
An optical sensor system is used for the Tape Start and
End Sensors on this equipment.  Carefully read and
follow the instructions below. Otherwise the unit may
operate erratically.
What to do for preparation
Insert a tape into the Deck Mechanism Assembly and
press the PLAY button. The tape will be loaded into the
Deck Mechanism Assembly. Make sure the power is on,
connect TP501 (S-INH) to GND. This will stop the function
of Tape Start Sensor, Tape End Sensor and Reel Sensors.
(If these TPs are connected before plugging in the unit,
the function of the sensors will stay valid.) See Fig. 1.
Note: Because the Tape End Sensors are inactive, do
not run a tape all the way to the start or the end of the tape
to avoid tape damage.
PREPARATION FOR SERVICING
Q504
Q503
TP501
S-INH
Fig. 1