DV-RW360H (serv.man10). Complete - Sharp DVD User Guide / Operation Manual. Page 2

Read Sharp DV-RW360H (serv.man10) User Guide / Operation Manual online

2
EN
Precautions
Before you start
Power Cord Protection
CAUTION:
USE OF CONTROLS OR ADJUSTMENTS OR 
PERFORMANCE OF PROCEDURES OTHER THAN 
THOSE SPECIFIED HEREIN MAY RESULT IN 
HAZARDOUS RADIATION EXPOSURE.
AS THE LASER BEAM USED IN THIS UNIT IS 
HARMFUL TO THE EYES, DO NOT ATTEMPT TO 
DISASSEMBLE THE CABINET. REFER SERVICING TO 
QUALIFIED PERSONNEL ONLY.
NOTE:
This unit can be used only where the power supply is 
AC 220–240V ~ ± 10%, 50Hz ± 0.5%. It cannot be used 
elsewhere.
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, 
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR 
MOISTURE.
TO REDUCE THE RISK OF FIRE OR ELECTRIC 
SHOCK, AND ANNOYING INTERFERENCE, USE THE 
RECOMMENDED ACCESSORIES ONLY.
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT 
EXPOSE THIS APPARATUS TO DRIPPING OR 
SPLASHING, NO OBJECTS FILLED WITH LIQUIDS, 
SUCH AS VASES, SHOULD BE PLACED ON THE 
APPARATUS.
Laser Diode Properties
Material:  
GaAs
Wave length: 
DVD:  658 nm
 CD: 
790 
nm
Emission Duration:   Continuous
Laser output:  
Max. 19 mW
To avoid any malfunctions of the unit, and to protect 
against electric shock, fire or personal injury, please 
observe the following.
•  Hold the plug firmly when connecting or disconnecting 
the AC power cord.
•  Keep the AC power cord away from heating appliances.
•  Never put any heavy object on the AC power cord.
•  Do not bundle any cables such as; AC power cord, 
Round Coaxial cable or other cables that are used to 
connect this unit to your TV together. Or never put 
any cables on the top panel of this unit. The noise or 
disturbance of the picture may be generated.
•  Do not attempt to repair or reconstruct the AC power 
cord in any way.
•  This unit is classified as a CLASS 1 LASER product.
•  The CLASS 1 LASER PRODUCT marking is embossed on 
the rear cover.
•  This product contains a low 
power laser device. To ensure 
continued safety, do not 
remove any cover or attempt 
to gain access to the inside of 
the product. Refer all 
servicing to qualified 
personnel.
AV1 (TV)
AV2 (DECODER)
DVD/VCR
DVD
ANTENNA
COAXIAL
S-VIDEO
OUT
AUDIO
OUT
DIGITAL
AUDIO OUT
COMPONENT
VIDEO OUT
L
R
Y
 PR
/CR
 PB
/CB
OUT
IN
CLASS 1 LASER PRODUCT
CLASSE 1 PRODUIT LASER
PRODUCT CON LASER CLASE 1
Supplied Accessory
•    Remote  control 
with two R6 (AA) size 
batteries
•   Round Coaxial cable
For Customer Use:
Read carefully the information located at the bottom 
of your unit and enter below the Serial No. Retain this 
information for future reference.
Model No.: VCR/DVD RECORDER COMBINATION: DV-RW360H
Serial No.: __________________________________
•   Operation Manual
•   Quick Start Guide
Connection to Power
SPECIAL NOTE FOR USERS IN THE U.K.
The mains lead of this product is fitted with a non-
rewireable (moulded) plug incorporating a 3A fuse. 
Should the fuse need to be replaced, a BSI or ASTA 
approved BS 1362 fuse marked   or 
ASA
 and of the same 
rating as above, which is also indicated on the pin face of 
the plug, must be used. Always refit the fuse cover after 
replacing the fuse. Never use the plug without the fuse 
cover fitted. In the unlikely event of the socket outlet in 
your home not being compatible with the plug supplied, 
cut-off the mains plug and fit an appropriate type.
DANGER:  The fuse from the cut-off plug should be 
removed and the cut-off plug destroyed 
immediately and disposed of in a safe manner. 
Under no circumstances should the cut-off 
plug be inserted elsewhere into a 13A socket 
outlet, as a serious electric shock may occur. 
To fit an appropriate plug to the mains lead, 
follow the instructions below:
IMPORTANT: The wires in 
the mains lead are coloured 
in accordance with the 
following code:
Blue: Neutral
Brown: Live
As the colours of the wires 
in the mains lead of this product may not correspond 
with the coloured markings identifying the terminals in 
your plug, proceed as follows:
-  The wire which is coloured blue must be connected to 
the plug terminal which is marked N or coloured black.
-  The wire which is coloured brown must be connected 
to the plug terminal which is marked L or coloured red.
Ensure that neither the brown nor the blue wire is 
connected to the earth terminal in your three-pin plug.
Before replacing the plug cover make sure that:
-  If the new fitted plug contains a fuse, its value is the 
same as that removed from the cut-off plug.
-  The cord grip is clamped over the sheath of the mains 
lead and not simply over the lead wires.
IF YOU HAVE ANY DOUBT, CONSULT A QUALIFIED 
ELECTRICIAN.
FUSE
BLUE
(Neutral)
BROWN
(Live)
CORD GRIP
OUTER SHEATH OF THE WIRE
Note:  A 5A fuse is also acceptable for a non-rewireable 
(moulded) plug which is used for this product.
Quick Start Guide for DV-RW360H
Accessories
Connection
How to install the batter-
Page of 100
Display

Click on the first or last page to see other DV-RW360H (serv.man10) service manuals if exist.