XL-S10H (serv.man11) - Sharp Audio Service Manual (repair manual). Page 5

Read Sharp XL-S10H (serv.man11) Service Manual online

XL-S10H
2 – 1
Audio
XL-S10H
Service Manual
XS10H
Market
E
 
CHAPTER 2. 
ADJUSTMENTS
[1] ADJUSTMENT
1. MECHANISM SECTION
 Driving Force Check
 Torque Check
 Tape Speed
2. TUNER SECTION
fL: Low-range frequency
fH: High-range frequency
 AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
 Check FM VT
Signal generator: 1 kHz, 40 kHz dev., FM modulated
 FM Mute Level
Signal generator: 1 kHz, 40 kHz dev., FM modulated
 FM Detection
Signal generator: 10.7 MHz FM sweep generator
 FM RF
Signal generator: 1 kHz, 75 kHz dev., FM modulated
3. CD SECTION
Adjustment
Since this CD system incorporates the following automatic adjust-
ment functions, readjustment is not needed when replacing the
pickup. Therefore, different PWBs and pickups can be combined
freely.
Each time a disc is changed, these adjustments are performed
automatically. Therefore, playback of each disc can be performed
under optimum conditions.
Torque Meter
Specified Value
Play: TW-2111
Over 80 g
Torque Meter
Specified Value
Play: TW-2111
30 to 80 g.cm
Fast forward: TW-2231
70 to 180 g.cm
Rewind: TW-2231
70 to 180 g.cm
Test Tape
Adjusting 
Point
Specified 
Value
Instrument 
Connection
MTT-111
Variable 
Resistor in 
motor.
3,000 ± 30 Hz
Speaker Ter-
minal (Load 
resistance: 6 
ohms)
Figure 1
Test Stage
Frequency
Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
IF
450 kHz
1,602 kHz
L305
*1
AM Band 
Coverage
522 kHz
(fL): L306
1.1 ± 0.1 V
*2
AM Tracking
990 kHz
990 kHz
L302
*3
*1. Input: IC301 1Pin
Output: IC301 23Pin
*2. Input: Input is not connected
Output: TP-VT(IC301 28Pin)
*3. Input: Antenna
Output:IC301 23Pin
Frequency
Display
Check 
Point
Instrument
Connection
87.5 MHz
87.5 MHz
1.5V ± 1.0V
TP-VT
108 MHz
108 MHz
5.0V ± 1.0V
TP-VT
TAPE MECHANISM
VARIABLE RESISTOR
IN MOTOR
Frequency
Display
Adjusting 
Parts
Instrument
Connection
98.00 MHz
(30 dB
µV)
98.00 MHz
Input: Antenna
Output: Speaker Terminal
Test 
Stage
Frequency
Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
FM IF
10.7 MHz
98.00 MHz
Input: Pin 36 of 
IC301
Output: Pin 23 
of IC301
Test 
Stage
Frequency
Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
FM Band 
Coverage
87.50 MHz
(fL): L307
1.5 ± 0.1 V
*1
FM RF 
98.00 MHz
(10 ~ 20dB)
98.00 MHz
L304
*1
*1. Input: Antenna
Output: 23 Pin of IC301
Figure 2 ADJUSTMENT POINTS
CNP301
L306
IC301
L304
FM RF
L302
L307
L305
MAIN PWB-A1
AM IF
AM ANT.
FM OSC.
FM BAND
COVERAGE fL
AM BAND
COVERAGE fL
TP-VT=28Pin
AM
Tracking
Page of 44
Display

Click on the first or last page to see other XL-S10H (serv.man11) service manuals if exist.