XL-HP404 (serv.man5). (2) Adjustments - Sharp Audio Service Manual (repair manual). Page 2

Read Sharp XL-HP404 (serv.man5) Service Manual online

XL-HP404E/HP404H
2 – 2
[2] TEST MODE
 Setting the test mode
During stand-by mode, press ON/STAND-BY button while pressing
down the 
button and X-BASS/DEMO button. then, press the CD
button to enter the test mode.
IL isn’t done
OPEN/CLOSE operation is using manual.
IL isn’t done
<<
>>,<<
>>buttons make pick's slide possible.
IL isn’t done
to page 2-3
<<PLAY>> key input.
C D
T E S T
A
Do TOC IL. Do normal play.
When these following key is input into PLAY key, track num-
ber can be appoint directly.
<<MEMORY>>
key input.
<<
1>> key: Track 4
<<
2>> key: Track 9
<<
3>> key: Track 15
Adjustment result automatically will
display as below for each 2 sec:
a) "FOF_XXXX"
b) "TOF_XXXX"
c) "TBAL_XX"
d) "TGAN_XX"
f) "FGAN_XX"
g) "RFLS_XX"
––––––––
<<STOP>> key input.
STOP
explanation:
a) Focus off set
= "FOF_XXXX"
b)Tracking off set
= "TOF_XXXX"
c)Tracking balance
= "TBAL_XX"
d)Tracking Gain
= "TGAN_XX"
f) Focus Gain
= "FGAN_XX"
g) RF level shift
= "RFLS_XX"
VOL — Last memory
P.GEQ — FLAT
X-BASS — OFF
To cancel : Power OFF
Page of 4
Display