Read Sharp XL-HF401PH (serv.man8) Technical Bulletin online
AUD 2013 04 01
Date of Issue: 15
th
April 2013
Classification:
White
AUDIO TECHNICAL BULLETIN
Page 2 of 2
Sharp Electronics (UK) Limited
Reference
– TSI-121Y0007
Revision - 1
White
– Carry out as required
Yellow
– Carry out as required and whenever the unit comes in for service
Red
– Carry out on all units
TIMER STANDBY LED indication
Light up
Light up
Updating error. The software will become unstable and cannot function.
The software will need to be loaded again by using the flash writer.
The software will need to be loaded again by using the flash writer.
Blinking
Updating under process. This may takes about 20 minutes.
Warning:
Warning:
DO NOT INTERRUPT
Off
Updating completed. The CD tray will automatically open.
Remove the disc and press the ON/STANDBY button on the set.
The display will show "Clear All" and the update process is complete.
Remove the disc and press the ON/STANDBY button on the set.
The display will show "Clear All" and the update process is complete.
To confirm the System Micom software version after the completed software update
1. Put the XL-HF401PH in STANDBY mode.
2. On the remote, press 1-> 2 -> 4 -> 5 buttons on the remote control in sequence.
2. On the remote, press 1-> 2 -> 4 -> 5 buttons on the remote control in sequence.
The current version of firmware will appear on the display.
The newly updated version will be displayed as "HF401* YYMMDDA"
Note:
YY - last 2 digit of year, ex; 2012 -> 12
MM - month, ex; March -> 03
DD - day, ex; 13th -> 13
A - version number in each date, ex; 1st version -> A
* - Destination
The newly updated version will be displayed as "HF401* YYMMDDA"