SYMPTOM Tape deck one will not play tapes.
CAUSE
Over stroke lever ( item 24 ) bends, disengaging tape one.
ACTION
Bend item 24 as shown in the diagram below.
Display

Download Sharp WQ-CH900H (serv.man6) Technical Bulletin

Here you can read online and download Sharp WQ-CH900H (serv.man6) Technical Bulletin in PDF. WQ-CH900H (serv.man6) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp WQ-CH900H (serv.man6) Portable. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.