CHAPTER 7. 
FLOWCHART
[1] Troubleshooting
1. When the CD does not function
The CD section may not operate when the objective lens of the optical pickup is dirty. Clean the objective lens, and check the playback operation.
When this section does not operate even after the above step is taken, check the following items.
Remove the cabinet and follow the trouble shooting instructions.
“Track skipping and/or no TOC (Table Of Contents) may be caused by build up of dust other foreign matter on the laser pickup lens. Before attempting
any adjustment make certain that the lens is clean. If not, clean it as mentioned below.”
Turn the power off.
Gently clean the lens with a lens cleaning tissue and a small amount of isopropyl alcohol.
Do not touch the lens with the bare hand. 
Parts code
1.
CD optical pickup Lens cleaner disc
UDSKA0004AFZZ
HOW TO USE
CAUTION
Cleaning fluid
Cleaner disc
Using the brush in the cleaner cap, apply 1 or 2 drops of the cleaning fluid to the
brush on the CD cleaner disc which has the mark next to it.
Place the CD cleaner disc onto the CD disc tray with the brush side down, then
press the play button.
You will hear music for about 20 seconds and the CD player will automatically stop.
If it continuous to turn, press the stop button.
1.
2.
3.
The CD lens cleaner should be effective for 30-50 operations, however if the
brushes become worn out earlier then please the cleaner disc.
If the CD cleaner brushes become very wet then wipe off any excess fluid with a soft
cloth.
Do not drink the cleaner fluid or allow it to come in contact with the eyes. In the
event of this happening then drink and / or rinse with clean water and seek medical
advice.
The CD cleaner disc must not be used on car CD players or on computer CD-ROM
drives.
All rights reserved. Unauthorized duplicating, broadcasting and renting this product
is prohibited by law.
SD-PX15H
7 – 2
2. DVD section
• “No Disc” is displayed. (Focus error)
Does the objective lens move up and down after the disc is 
removed ? (Check the following items.)
No
“No Disc” is displayed.
Refer to “When the focus servo does not function”.
     
Yes
Is signal input to pins 122 - 125 of IC3001 ?
No
Check connection of optical pickup cables.
If no abnormality is detected, replace optical pickup.
     
Yes
Is focus control signal output to pin 152 of IC3001 ?
No
Check circuits around the power supply for pin 149 of IC3001.
If no abnormality is detected, replace IC3001.
     
Yes
Is focus control signal output from pin 152 of IC3001 to pin 23 of 
IC3704 ?
No
Check focus control signal line between IC3001 and IC3704.
Check M8V line.
     
Yes
No
Is focus control drive voltage output from pins 1 and 28 of 
IC3704 ?
No
Is voltage of 8 V applied to pin 22 of IC3704 ?
 Yes
Check that pin 16 of IC3704 is “H” and replace IC3704.
If pin 16 of IC3704 is “L”, check pin 73 of IC3001.
     
Yes
Is focus control drive voltage applied to the focus actuator termi-
nal ?
No
Check line between IC3704 and focus actuator terminal. Check 
CN3301.
     
Yes
Check connection of optical pickup cables.
If no abnormality is detected, replace the traverse chassis.
• “No Disc” is displayed during DVD playback (when CD is playable) ... When DVD laser does not light up.
Is control signal output from pin 133 of IC3001 ?
No
Check and replace IC3001.
     
Yes
Is voltage of 5 V applied to emitter of Q3306 ?
No
Check S5V line.
     
Yes
Is voltage of approx. 2 V supplied to pin 2 of CN3301 ?
No
Check around Q3305 and Q3306.
     
Yes
Check connection of optical pickup cables.
If no abnormality is detected, replace traverse chassis.
Note: The laser diode is easily damaged by static electricity.
Carefully check static electricity and electric leak of the measuring 
instrument.
SD-PX15H
7 – 3
• “No Disc” is displayed during CD playback (when DVD is playable) ... When CD laser does not light up.
Is control signal output from pin 135 of IC3001 ?
No
Check and replace IC3001.
     
Yes
Is voltage of 5 V applied to the emitter of Q3304 ?
No
Check S5V line.
     
Yes
Is voltage of approx. 2 V supplied to pin 6 of CN3301 ?
No
Check around Q3303 and Q3304.
     
Yes
Check connection of optical pickup cables.
If no abnormality is detected, replace traverse chassis.
Note: The laser diode is easily damaged by static electricity.
Carefully check static electricity and electric leak of the measuring 
instrument.
Put a disc on the DISC tray.
Yes
Disc normally loaded?
Yes
Check loading switch.
No
Is RF signal level output from pin 17 of
CN3301 normal ?
Yes
Is objective lens of optical pickups clean?
No
Yes
Replace main PWB.
Replace traverse chassis.
No
Refer to "Video is not output normally" and
"Audio is not output normally".
Yes
Both video and audio do not operate normally.
SD-PX15H
7 – 4
• Video is not output normally.
Put a disc on the DISC tray.
     
Yes
Is video signal input to each pin of IC3201 as shown below ?
IC3201      2 pin    S-C
IC3201      6 pin    S-Y
IC3201    10 pin    Py
IC3201    12 pin    Pb
IC3201    14 pin    Pr
No
Check the main unit. (Circuits around IC3001 and IC3201.)
Check S5V line.
     
Yes
  
No
Video signals input to each pin of IC3201 as shown below ?
IC3201    26 pin    S-C
IC3201    23 pin    COMP
IC3201    21 pin    S-Y
IC3201    20 pin    Py
IC3201    18 pin    Pb
IC3201    16 pin    Pr
No
Is voltage of approx. 5 V supplied to pins 1 and 28 of IC3201 ?
      
Yes
      
Yes
Do V-MUTE line for pins 3 and 13 of IC3201 reach “H” level ?
                         
Yes
Replace IC3201.
     
No
Check V-MUTE line.
Is video signal output to each pin of main unit connector 
CNP601 as shown below?
CNP601    1 pin    V
CNP601    2 pin    S-C
CNP601    3 pin    S-Y
CNP601    5 pin    Pr
CNP601    6 pin    Pb
CNP601    7 pin    Pr
No
Check between CN3201 and CNP601.
     
Yes
Is each video signal output to the specified output terminal ?
Is combined video signal output to VIDEO OUT terminal (JK601) 
?
No
Check line from pin 1 of CNP601 to VIDEO OUT terminal (JK601) 
and VIDEO OUT terminal (JK601).
Is brightness signal output to S-OUT terminal (SO602) ?
No
Check line from pin 3 of CNP601 to S-OUT terminal (SO602) and 
S-OUT terminal (SO602).
Is chrominance signal output to S-OUT terminal (SO602) ?
No
Check line from pin 2 of CNP601 to S-OUT terminal (SO602) and 
S-OUT terminal (SO602).
Is brightness signal output to pin 1 of SCART OUT terminal 
(SO601) ?
No
Check line from pin 7 of CNP601 to pin 1 of SCART OUT terminal 
(SO601) and the SCART OUT terminal (SO601).
Is chrominance difference signal (Pb) output to pin 3 of SCART 
OUT terminal (SO601) ?
No
Check line from pin 6 of CNP601 to pin 3 of SCART OUT terminal 
(SO601) and SCART OUT terminal (SO601).
Is chrominance difference signal (Pr) output to pin 5 of SCART 
OUT terminal (SO601) ?
No
Check line from pin 5 of CNP601 to pin 5 of SCART OUT terminal 
(SO601) and SCART OUT terminal (SO601).
Page of 5
Display

Download Sharp SD-PX15H (serv.man18) Service Manual (Repair Manual)

Here you can read online and download Sharp SD-PX15H (serv.man18) Service Manual in PDF. SD-PX15H (serv.man18) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp SD-PX15H (serv.man18) System. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.