Read Sharp QT-CD250 (serv.man6) Service Manual online
QT-CD250H/W
– 18 –
NOTES ON SCHEMATIC DIAGRAM
1. Tuner
( ): AM mode
Marking except for ( ): FM mode
Marking except for ( ): FM mode
2. CD
( ): Play mode
Marking except for ( ): Stop state
Marking except for ( ): Stop state
3. Deck section
( ): Record mode
Marking except for ( ): Playback mode
Display / Control section:
( ): Active state
Marking except for ( ): CD Function mode at stop state
Marking except for ( ): Playback mode
Display / Control section:
( ): Active state
Marking except for ( ): CD Function mode at stop state
• Schematic diagram and Wiring Side of P.W.Board for this
model are subject to change for improvement without prior
notice.
notice.
• Parts marked with “ ” (
) are important for
maintaining the safety of the set. Be sure to replace these
parts with specified ones for maintaining the safety and
performance of the set.
parts with specified ones for maintaining the safety and
performance of the set.
• Resistor:
To differentiate the units of resistors, the symbol as K and M
are used: the symbol K means 1000 ohm and the symbol M
means 1000 kohm and the resistor without any symbol is an
ohm resistor. The resistor designated "Fusible" is a fuse type
resistor
are used: the symbol K means 1000 ohm and the symbol M
means 1000 kohm and the resistor without any symbol is an
ohm resistor. The resistor designated "Fusible" is a fuse type
resistor
• Capacitor:
To indicate the unit of capacitor, a symbol P is used: this
symbol P means micro-micro-farad and the unit of the capacitor
without such a symbol is microfarad. As to electrolytic capacitor,
the expression “capacitance/withstand voltage” is used.
(CH), (TH), (RH), (UJ): Temperature compensation
(ML): Mylar type
(P.P.): Polypropylene type
symbol P means micro-micro-farad and the unit of the capacitor
without such a symbol is microfarad. As to electrolytic capacitor,
the expression “capacitance/withstand voltage” is used.
(CH), (TH), (RH), (UJ): Temperature compensation
(ML): Mylar type
(P.P.): Polypropylene type
• The indicated voltage in each section is the one measured by
Digital Multimeter between such a section and the chassis
with no signal given.
with no signal given.
SW102
RECODE/PLAYBACK
REC—P.B.
SW201
FUNCTION SELECTOR
TAPE/OFF—
TUNER/ON—CD/ON
TUNER/ON—CD/ON
SW601
TAPE MAIN
OFF—ON
SW651
VOLTAGE SELECTOR
AC220-240V—
(QT-CD250W ONLY)
AC110-127V
SW702
PICKUP IN
OFF—ON
SW801
PLAY/PAUSE/
OFF—ON
TUNING UP
SW802
STOP/TUNING DOWN
OFF—ON
SW803
REPEAT/BAND
OFF—ON
SW804
TUNER/MEMORY
OFF—ON
SW805
CUE/PRESET UP
OFF—ON
SW806
REVIEW/
OFF—ON
PRESET DOWN
SW807
VOLUME UP
OFF—ON
SW808
VOLUME DOWN
OFF—ON
SW809
X-BASS
OFF—ON
SW810
CD LID
OFF—ON
REF. NO
DESCRIPTION
POSITION
Figure 18 TYPES OF TRANSISTOR
E C B
(S) (G) (D)
(1) (2) (3)
FRONT
VIEW
KRA102 M
KRC107 M
KTA1046 Y
KTA1266 GR
KTA1273 Y
KTC3199 GR
KRC107 M
KTA1046 Y
KTA1266 GR
KTA1273 Y
KTC3199 GR
Click on the first or last page to see other QT-CD250 (serv.man6) service manuals if exist.