QT-CD210 (serv.man3) - Sharp Audio Service Manual (repair manual). Page 3

Read Sharp QT-CD210 (serv.man3) Service Manual online

QT-CD210H/W
– 3 –
IMPORTANT SERVICE NOTES (QT-CD210H FOR U.K. ONLY)
VOLTAGE SELECTION (QT-CD210W ONLY)
The voltage selector is located on the AC voltage selector box. If adjustment is necessary, use a screwdriver in order to turn the
selector in either direction unitil the correct voltage figure is displayed in the window next the adjustment screw.
QACCA0001SJ00
QACCB0001SJ00
QACCE0001SJZZ
QPLGA0250AFZZ
QPLGA0253AFZZ
QT-CD210H for Europe
QT-CD210H for U.K.
PROBE
AC
OUT
UNIT
SHORT-CIRCUT
AC POWER
SUPPLY CORD
CONNECT THE PROBE
TO GND OF CHASSIS
SCREW TERMINAL
WITHSTANDING
VOLTAGE TESTER
LASER KLASSE 1
LUOKAN 1 LASERLAITE
KLASS 1 LASERAPPARAT
Before returning the unit to the customer after completion of a
repair or adjustment it is necessary for the following withstand
voltage test to be applied to ensure the unit is safe for the
customer to use.
Setting of Withstanding Voltage Tester and set.
NG: The “NG” lamp lights and the buzzor sounds.
OK: The “GOOD” lamp lights.
Judgment
Unit
Set current (Cutoff current)
Set time
Set name
Withstanding Voltage Tester
Test voltage
Set value
4,240 VPEAK
3,000 VRMS
6 secs
4 mA
AC POWER SUPPLY CORD AND AC PLUG ADAPTOR (FOR QT-CD210W)
Page of 36
Display

Click on the first or last page to see other QT-CD210 (serv.man3) service manuals if exist.