QT-CD161H (serv.man2) - Sharp Audio User Guide / Operation Manual. Page 3

Read Sharp QT-CD161H (serv.man2) User Guide / Operation Manual online

QT-CD141H/161H/162H
– 3 –
FOR A COMPLETE DESCRIPTION OF THE OPERATION OF THIS UNIT, PLEASE REFER
TO THE OPERATION MANUAL.
SPECIFICATIONS
    General
Power source:
AC 230 - 240V, 50 Hz
DC 12 V [ "D" size (UM/SUM-1,
R20 or HP-2) battery x 8]
DC 3 V ["AA" size (UM/SUM-3, R6
or HP-7) battery x 2 for tuner
memory]
Power consumption:
11 W
Output power:
PMPO; 28 W (total)
(161H Except forU.K.
MPO; 8.4 W (4.2 W + 4.2 W)
/141H/162H)
(AC operation, DIN 45 324)
RMS; 4.6 W (2.3 W + 2.3 W)
(DC operation, DIN 45 324)
Output power:
MPO; 8.4 W (4.2 W + 4.2 W)
(161H For U.K.)
(AC operation 10% T.H.D.)
RMS; 4.6 W (2.3 W + 2.3 W)
(DC operation, 10 % T.H.D.)
Speakers:
10 cm (4") full-range speaker x 2
Output terminal:
Headphones; 16-50 ohms
(recommended; 32 ohms)
Dimensions:
Width; 480 mm (18-15/16")
Height; 153 mm (6-1/16")
Depth; 254 mm (10")
Weight:
3.2 kg (7.1 Ibs.) without batteries
    Radio
Frequency range:
FM; 87.5 - 108 MHz
AM; 526.5 - 1,606.5 kHz
    Tape recorder
Frequency response:
50 - 14,000 Hz (Normal tape)
Signal/noise ratio:
50 dB
Wow and flitter:
0.3 % (DIN 45 511)
(161H Except for U.K./Australia/New Zealand/141H/162H)
Wow and flitter:
0.25 % (WRMS)
(161H For U.K./Australia/New Zealand)
Motor:
DC 12 V electric governor
Bias system:
AC bias
Erase system:
Magnet erase
    Compact disc player
Disc:
Compact disc
Signal readout:
Non-contact, 3-beam semi-
conductor laser pickup
Audio channels:
2
Quantization:
16-bit linear quantization
Filter:
4-tims oversampling digital filter
D/A converter:
1-bit D/A converter
Wow and flutter:
Unmeasurable
(less than 0.001% W. peak)
Specifications for this model are subject to change without
prior notice.
IMPORTANT SERVICE NOTES (161H FOR U.K. ONLY)
Before returning the unit to the customer after completion of a repair or adjustment it is necessary for the following withstand voltage
test to be applied to ensure the unit is safe for the customer to use.
Setting of Withstanding Voltage Tester and set.
NG: The “NG” lamp lights and the buzzor sounds.
OK: The “GOOD” lamp lights.
Judgment
Unit
Set current (Cutoff current)
Set time
Set name
Withstanding Voltage Tester
Test voltage
Set value
4,240 VPEAK
3,000 VRMS
6 secs
4 mA
PROBE
AC
OUT
UNIT
SHORT-CIRCUT
AC POWER
SUPPLY CORD
CONNECT THE PROBE
TO GND OF BATTERY 
SPRING
WITHSTANDING
VOLTAGE TESTER
Page of 40