Read Sharp HT-SB60 (serv.man5) Technical Bulletin online
AUD 2013 04 09
Date of Issue: 30
th
April 2013
Classification:
Yellow
AUDIO TECHNICAL BULLETIN
Page 1 of 4
Sharp Electronics (UK) Limited
Reference
– TSI-1340005
Revision - 2
White
– Carry out as required
Yellow
– Carry out as required and whenever the unit comes in for service
Red
– Carry out on all units
MODELS
HT-SB60
REASON
The sound bar may power off randomly during operation.
ACTION
If this problem happens randomly or permanently, replace IC805 and add the
additional heat sink.
additional heat sink.
If your unit requires this update, you should have this repaired via our central service
contractor. Telephone - 0845 880 0512.
Note
contractor. Telephone - 0845 880 0512.
Note
– Units not covered under the manufacturer’s warranty will be chargeable.
Check the serial number of the unit and repair as required using the new part code.
Affected serial number range - 20800004
~21201057
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
IC805
LDO IC 1.8V
VHiNCP60318T1
AD
Heat Sink (IC Angle)
LANGKA278AWZZ
AF
Heat Transfer Sheet
PSPAZA037AWZZ
AC
AUD 2013 04 09
Date of Issue: 30
th
April 2013
Classification:
Yellow
AUDIO TECHNICAL BULLETIN
Page 2 of 4
Sharp Electronics (UK) Limited
Reference
– TSI-1340005
Revision - 2
White
– Carry out as required
Yellow
– Carry out as required and whenever the unit comes in for service
Red
– Carry out on all units
1. Replace the defective IC805 with the replacement part.
AUD 2013 04 09
Date of Issue: 30
th
April 2013
Classification:
Yellow
AUDIO TECHNICAL BULLETIN
Page 3 of 4
Sharp Electronics (UK) Limited
Reference
– TSI-1340005
Revision - 2
White
– Carry out as required
Yellow
– Carry out as required and whenever the unit comes in for service
Red
– Carry out on all units
2. Addition of heatsink and transfer sheet.
AUD 2013 04 09
Date of Issue: 30
th
April 2013
Classification:
Yellow
AUDIO TECHNICAL BULLETIN
Page 4 of 4
Sharp Electronics (UK) Limited
Reference
– TSI-1340005
Revision - 2
White
– Carry out as required
Yellow
– Carry out as required and whenever the unit comes in for service
Red
– Carry out on all units
3. Fit the heatsink using the screw indicated in the photo below.