DK-KP95PH (serv.man3) - Sharp Audio Service Manual (repair manual). Page 10

Read Sharp DK-KP95PH (serv.man3) Service Manual online

DK-KP95PH
4 – 2
(1) Focus-HF system check.
Figure 2
Figure 3
118
117
IC1
IC1
1
FOP
TRP
Figure 1
Press the Tray1 CD Eject Button without inserting a disc, and try 
starting the playback operation.
2. Does the focus (lens) move up and down ?
    (Waveform drawing Figure 1)
1. Is focus servo activated ?
    (Waveform drawing Figure 2)
2. Is the HF waveform normal ?
    (Waveform drawing Figure 3)
1. Does the pickup move to the PICKUP-IN Switch position ?
Sled motor.
Check the focus peripheral circuit.
Check the laser diode driver Q5 peripheral circuit.
Spindle motor.
If the level is not normal.
Pins 114, 115, 117, 118 (122~129) on IC1.
Check the laser diode driver Q5 peripheral circuit.
3. Is the laser lit ?
4. Is the turntable rotating ?
When a disc is loaded, start playback operation.
Although a CD is inserted and the cover is 
closed, "NO DISC" is displayed.
Yes
Yes
Yes
Yes
No
No
No
No
No
No
2
118
78
IC1
IC1
1
FOP
TE
4
134
IC1
RFOUT
7
Page of 54
Display

Click on the first or last page to see other DK-KP95PH (serv.man3) service manuals if exist.