CD-SW340H - Sharp Audio Service Manual (repair manual). Page 10

Read Sharp CD-SW340H Service Manual online

CD-SW340H
2 – 3
Sliding the PICKUP with <<
>>, <<
>> button
must only be in STOP mode.
<<MEMORY>> key input.
Laser ON.
<<MEMORY>> key input.
Tracking OFF play at that specific point.
<<MEMORY>> key input.
Tracking ON play from that specific point.
<<MEMORY>> key input.
Adjustment result automatically will display as below for each 2 sec :
a) "FOF_XXXX"
b) "TOF_XXXX"
c) "TBAL_XX"
d) "TGAN_XX"
f) "FGAN_XX"
g) "RFLS_XX"
<<STOP>> key input.
STOP
Explanation:
a) Focus off set
= "FOF_XXXX"
b) Tracking off set
= "TOF_XXXX"
c) Tracking balance
= "TBAL_XX"
d) Tracking Gain
= "TGAN_XX"
f) Focus Gain
= "FGAN_XX"
g) RF level shift
= "RFLS_XX"
VOL — Last memory
P.GEQ — FLAT
X-BASS — OFF
To cancel: Power OFF
A
Page of 96