CD-MPS660H (serv.man22) - Sharp Audio Service Manual (repair manual). Page 11

Read Sharp CD-MPS660H (serv.man22) Service Manual online

CD-MPS660H/CD-MPS660E
2 – 4
[5] CD section
CD Error code description
* 'CHECKING'
If Error is detected, 'CHECKING' will be displayed instead of 'ER-
CD**'. 'ER-CD**' display will only be displayed when error had been
detected for the 5th times.
Standard Specification of Stereo System Error Message Display Contents
(*) CHECKING:
If CD changer mechanism error is detected, 'CHECKING' will be dis-
play instead of 'ER-CD**'. 'ER-CD**' display will only be display when
error had been detected for the 5 th times.
Speaker abnormal detection and +B PROTECTION display
In case speaker abnormal detection or +B PROTECTION had
occurred, it can be check by pressing 'POWER', '
' and 'X-BASS'
button. MicroComputer version number will displayed as "XM******".
Press ‘VIDEO/AUX’ button during version number display and then
press ‘POWER’, ‘MEMORY/SET’ and ‘VIDEO/GAME’ button. Display
will show "S** B**". S is referring to speaker abnormal detection and B
is referring to +B PROTECTION. ** is in hex valve.
+B PROTECTION is condition when irregular process occur on power
supply line.
BEFORE TRANSPORTING THE UNIT
The following process need to be taken after set tapering/parts
replacement.
1. Press the ON/STAND-BY button to enter stand-by mode.
2. While pressing down the 
button and the X-BASS/DEMO but-
ton, press the ON/STAND-BY button. The Micro Computer version
number will be displayed as "XM******".
3. Press OPEN/CLOSE button until "WAIT"
→ "FINISHED" appears.
4. Unplug the AC cord and the unit is ready for transporting.
Error
Explanation
01
When Pickup set inner position, inner switch cannot detect 
'ON' level for 10 secs.
10*
CAM error. Can't detect CAM switch when CAM is moving.
11*
When it detect cam operation error during initialize pro-
cess.
20*
TRAY error. Can't detect TRAY switch when TRAY is mov-
ing.
21*
When it detect TRAY operation error during initialize pro-
cess.
31
When it change to CD function, DSP cannot read initial 
data.
Error Contents
Display
Notes
CD
Pickup Mechanism Error.
'ER-CD01'
PU-IN SW Detection NG.
CD Changer Mechanism Error.
'ER-CD**' (*)
10: CAM SW Detection NG during normal operation
11: CAM SW Detection NG during initialize process
20:TRAY SW Detection NG during normal operation
21:TRAY SW Detection NG during initialize process
CD DSP Communication Error.
'ER-CD31'
DSP COMMUNICATION ERROR.
Focus Not Match/IL Time Over.
'NO DISC'
TUNER
PLL Unlock.
PLL Unlock.
FM  87.50  MHz
Page of 127
Display

Click on the first or last page to see other CD-MPS660H (serv.man22) service manuals if exist.