CD-E250 (serv.man10). Test mode - Sharp Audio Service Manual (repair manual). Page 3

Read Sharp CD-E250 (serv.man10) Service Manual online

CD-E250E
CD-E550E
– 14 –
3.Preset frequencies for various destinations
(random preset memory)
BAND
6
AM  530 kHz
7
AM1720 kHz
8
AM
AM  990 kHz
9
AM  600 kHz
10
AM1400 kHz
AM
CH
BAND
16-35
36
FM106.0 MHz
37
FM  90.0 MHz
38
FM
FM  98.0 MHz
39
MONO
FM108.0 MHz
40
FM  87.5 MHz
FM
CH
• The slant line sections of the table store no memory.
BAND
1
FM  87.5 MHz
2
FM108.0 MHz
3
FM
FM  98.0 MHz
4
STEREO
FM  90.0 MHz
5
FM106.0 MHz
FM
CH
4. Electronic volume Test Mode (TEST 3)
When this test mode is obtained, the following display lights
for one second.
In this mode, volume is Volume -14 dB (STEP 23), FLAT
AND X-BASS ON, and start-up function to CD, respectively.
The button operations in the test mode are the same as
those of ordinary operation except volume UP/DOWN.
(1) The display is the same as that of ordinary operation
except test mode setting.
(2)  Unlike the ordinary state, the volume is controlled with
the volume UP/DOWN button in accordance with the
following three steps.
      Volume- 
 
(STEP 0) <-> Volume-14 dB (STEP 23) <-
> Volume-0 (STEP 30)
(3) X-BASS is switched when button is pressed..
5. Timer test Mode (TEST 4)
When this test mode is obtained, the following display lights
for one second.
Set the current time and timer time according to the following
procedure to reproduce the timer.
1.Set the current time to 1:00, the timer to ON time 1:05, the
function to CD, and volume to STEP 12, respectively.  One
minute is counted as one second, and the timer is reproduced.
The fade-in (when playback is started) is executed at a rate
of one step for 1 sec.  After completion of fade-in, the fade-
out is executed at a rate of one step for 1 sec (WAIT 1 sec
inserted).
  After completion of fade-out, the power is turned off (after
WAIT 1 sec), and the mode is shifted to the standby.
  The display during operation is the same as that of ordinary
timer operation.
6. FL Test Mode (TEST 5)
When the FL test mode is obtained, all the FL segments are
lighted. Then pressing the "PLAY" button switches display
as below.
Lighting of all segments
Lighting of odd segments
Lighting of even segments
Page of 4