CD-DP2500H
– 16 –
CD SECTION
• 
 AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
*1. Input: Antenna
Output: TP302
*2. Input: Antenna
Output: TP301
TUNER SECTION
fL: Low-range frequency
fH: High-renge frequency
AM IF
450 kHz
1,620 kHz
T351
*1
AM Band
522 kHz
(fL): T306
*2
Coverage
1.1 
±
 0.1 V
AM Tracking 990 kHz
990 kHz
(fL): T303
*1
Figure 16-1 ADJUSTMENT POINT
Test Stage
Frequency
Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
Figure 16-2
CD ERROR CODE DESCRIPTION
Error
State Code
[Servo System Error]
0001
Cannot detect Pickup-in SW
0002
DSP access error
[Error during close operation]
0101
Open/Close SW not functioning (Low 
 High)
0103
Open/Close SW not functioning (High 
 Low)
[Error during open operation]
0201
Open/Close SW not functioning (Low 
 High)
0203
Open/Close SW not functioning (High 
 Low)
[Error during skip operation]
0302
Pickup-in SW is not detected
0306
During Disc 1 search, Open/Close SW or Clamp SW
or Disc SW do not change to low.
0307
Clamp SW not function (Low 
 High)
0308
Clamp SW not function (High 
 Low)
Since this CD system incorporates the following automatic
adjustment functions, readjustment is not needed when
replacing the pickup. Therefore, different PWBs and pickups
can be combined freely.
Each time a disc is changed, these adjustments are
performed automatically. Therefore, playback of each disc
can be performed under optimum conditions.
Items adjusted automatically
(1) Offset adjustment (The offset voltage between the head
amplifier output and the VREF reference voltage is
compensated inside the IC.)
  * Focus offset adjustment
  * Tracking offset adjustment
(2) Tracking balance adjustment (waveform drawing 14-2
EFBL)
(3) Gain adjustment (The gain is compensated inside the IC
so that the loop gain at the gain crossover frequency will
be 0dB.)
  * Focus gain adjustment
  * Tracking gain adjustment
  Adjustment
T
T
EFBL
FDO
TE
Stopped
CH1=500mV
DC   10:1
CH2=200mV
DC   10:1
CH3=1V
DC   10:1
500ms/div
(500ms/div)
NORM:20kS/s
1
2
3
=Record Length=
Smoothing :   ON
CH1  :      0.000V
CH2  :      0.000V
Main  :     100K
Zoom  :       2k
Mode  :   SINGLE
Type   :   EDGE CH1
Delay  :                    0.0ns
Hold off  :                0.2us
CH3  :        0.00V
CH4  :        0.00V
BW   : FULL
=Trigger=
=Filter=
=Offset=
CH2
  v/DIV
   200mV
1999/04/05  20:26:47
T303
CF301
T351
CF352
CF351
CF302
IC303
T306
IC302
FE301
CNP301
 SO301
FM75 ohms
 AM LOOP
ANTENNA
MAIN PWB
AM Tracking
AM Band Coverage
AM IF
TP301
TP302
Page of 3