CD-C411H (serv.man3). Trouble shooting the CD section - Sharp Audio Service Manual (repair manual). Page 4

Read Sharp CD-C411H (serv.man3) Service Manual online

– 41 –
CD-C421H / C411H
Yes
No
The turntable rotates a little.
The turntable fails to rotate or rotates at high speed.
Yes
The spin driver circuit is normal.
Check the periphery of IC1 pins 23 to 27, pin 39, and pin 40, IC2
pin 12 and pin 13, IC5 to CNP3.
Yes
Figure 41
Play operation is performed when disc exits.
Yes
Although HF waveform is normal, TOC data cannot be read.
Yes
Check PDO waveform (Fig. 41).
Abnormal
Check the IC1 pins 43 and 44, IC2 pins 3, 5, 7, 10, and 11.
Stop --> Play
As VCO freque-
ncy is locked at
4.32 M Hz, voltage
of PDO rises and
stabili zes.
2
3
 0.5s
1.00 V
IC2   3   PDO
 0.5s
1.00 V
IC2  16   FD
•  Although HF waveform is normal and the time
indication is normal, no sound is emitted.
Check  IC 2 pin 48 (EFLG).
Check IC2 pins 37, 40.
Check IC 401 and POWER AMP IC 961.
Abnomal
Yes
Usually, the number of pulses of flawless disc is 100 pulses/sec
or less.
No
Page of 4
Display