Read Sharp CD-C410H (serv.man9) Technical Bulletin online
Sharp Electronics (UK) Limited CE Technical Support Group
Originator
$Y:
$Y:
Supervisor
Approval Date / / Reference EAA-813
White - Carry out as required Yellow - Carry out as required and whenever unit comes in for service Red - Carry out on all units
AUD970804
Month of Issue :
August 1997
Classification :
White
AUDIO TECHNICAL BULLETIN
Page 1 of 1
MODELS
CDC470H
CDC401H
CDC410H
CDC430H
SYMPTOM When tape two is put in the playback or record modes, it reverts to the stop
condition immediately
If on continuous play from tape one to tape two, tape two stop immediately it is
started.
started.
CAUSE
Auto stop mechanism operating erratically.
ACTION
Carry out the following modification to the mode lever ( Item 25 ).
1. Remove the old mode lever.
2. Before fitting new mode lever, apply grease as shown in the diagram below.
3. Fit the new mode lever.
2. Before fitting new mode lever, apply grease as shown in the diagram below.
3. Fit the new mode lever.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
25
Mode lever
MLEVF0015AWFW
??