Read Sharp CD-C401H (serv.man4) Technical Bulletin online
Sharp Electronics (UK) Limited
Reference EAA-919
Revision 1
White – Carry out as required, Yellow – Carry out as required and whenever the unit comes in for service, Red – Carry out on all units
AUD990502
Month of Issue: May 1999
Classification: White
AUDIO TECHNICAL BULLETIN
Page 1 of 1
MODELS
CDC401H
CDC407H
CDC411H
CDC421H
CDC423H
The models listed above will display an error code on the front panel display as indicated
below in a fault condition.
Please add this information to your service manual.
CDC401H and CDC407H
1
Open error
2
Changer no connection
3
Can not detect switch number
4
Disc number wrong detection (excluding disc number 0 or detect more than 4 times
5
Mecha up switch error
6
Can not detect open/close switch
7
Disc number switch error
CDC421H, CDC411H and CDC423H
3001
Tray open error (tray open fix waiting time out error)
3003
Tray open error (tray open fix waiting time out error)
0404
PU in switch error (internal point, time out can not find)
0406
PU in switch error (internal point, time out can not find)
0501
PU in switch error (internal point, time out can not find)
1004
PU in switch error (internal point, time out can not find)
0411
0412
0414
1011
1012
1014
Display