CD-BA3100 (serv.man2). Split - Section 1 - Text - 1-17 - Sharp Audio Service Manual (repair manual). Page 17

Read Sharp CD-BA3100 (serv.man2) Service Manual online

– 17 –
CD-BA3100H
TEST MODE
During POWER OFF mode, push below each 2 keys and [POWER] key. Then go to each Test Mode.
KEY
TEST MODE
CONTENTS
[CD] [X-BASS] + [POWER]
TEST 1
CD Test mode
[TAPE] [X-BASS] + [POWER]
TEST 2
Tape test mode
[TUNER] [X-BASS] + [POWER]
TEST 3
Tuner preset memory clear
[VIDEO/AUX] [X-BASS] + [POWER]
TEST 4
Tuner preset for production
[MEMORY/SET] [X-BASS] + [POWER]
TEST 5
All clear (reset)
[EQUALIZER] [X-BASS] + [POWER]
TEST 6
Audio test
[   ] [DIMMER] + [POWER]
TEST 7
Key and display test
[TUN UP] [DIMMER] + [POWER]
TEST 8
RDS Test1
[TUN DOWN] [DIMMER] + [POWER]
TEST 9
RDS Test2
 ] [CD] + [POWER]
TEST 10
CD Changer test
 ] [CD] + [POWER]
TEST 11
Production initialize for changer
[EQUALIZER] [TUN UP] + [POWER]
TEST 12
Graphic equalizer test
CD TEST MODE
• Setting the test mode
  Any one of test mode can be set by pressing several keys as follows.
  <X-BASS> + <CD> + <POWER> TEST: CD operation test.
Enter test 1 mode key.
C  D       T  E  S  T
OPEN/CLOSE operation is using manual.
Do TOC IL. Do normal play.
When these following key is input into PLAY key,
track number  can be appoint directly.
<<PLAY>> key input.
<<MEMORY>> key input.
Laser ON.
<<MEMORY>> key input.
Tracking OFF play at that specific point.
<<MEMORY>> key input.
<<
1>> key: Track 1
<<
2>> key: Track 3
<<
3>> key: Track 7
<<
4>> key: Track 11
<<
5>> key: Track 13
<<
6>> key: Track 15
Tracking ON play from that specific point.
<<MEMORY>> key input
a) Display
"FOFF_XX"
b) Display
"TOFF_XX"
c) Display
"TBAL_XX"
d) Display
"TGAN_XX"
e) Display
"FGAN_XX"
 f) Display
"RFLS_XX"
<< 
 >>, << 
 >> buttons make pick's slide possible.
<<STOP>> key input.
STOP
<<MEMORY>> key input.
a) Display
"FOFF_XX"
b) Display
"TOFF_XX"
c) Display
"TBAL_XX"
d) Display
"TGAN_XX"
e) Display
"FGAN_XX"
 f) Display
"RFLS_XX"
Display every auto setting result for every 2 sec.
<<STOP>> key input.
STOP
VOL
––
Last memory
BAL
––
CENTER
P.GEQ
––
FLAT
X-BASS
––
OFF
Sliding the PICKUP with
<< 
 >>, << 
 >> button
must only be in STOP mode.
Display each step for 2 sec.      XX: HEX VALUE
a) "FOFF_XX"
Focus off set
b) "TOFF_XX"
Tracking off set
c) "TBAL_XX"
Tracking balance
d) "TGAN_XX"
Tracking gain
e) "FGAN_XX"
Focus gain
f ) "RFLS_XX"
RF level shift
To cancel : Power OFF
Page of 17
Display