Read Sharp CD-BA3100 (serv.man2) Service Manual online
– 17 –
CD-BA3100H
TEST MODE
During POWER OFF mode, push below each 2 keys and [POWER] key. Then go to each Test Mode.
KEY
TEST MODE
CONTENTS
[CD] [X-BASS] + [POWER]
TEST 1
CD Test mode
[TAPE] [X-BASS] + [POWER]
TEST 2
Tape test mode
[TUNER] [X-BASS] + [POWER]
TEST 3
Tuner preset memory clear
[VIDEO/AUX] [X-BASS] + [POWER]
TEST 4
Tuner preset for production
[MEMORY/SET] [X-BASS] + [POWER]
TEST 5
All clear (reset)
[EQUALIZER] [X-BASS] + [POWER]
TEST 6
Audio test
[ ] [DIMMER] + [POWER]
TEST 7
Key and display test
[TUN UP] [DIMMER] + [POWER]
TEST 8
RDS Test1
[TUN DOWN] [DIMMER] + [POWER]
TEST 9
RDS Test2
[
] [CD] + [POWER]
TEST 10
CD Changer test
[
] [CD] + [POWER]
TEST 11
Production initialize for changer
[EQUALIZER] [TUN UP] + [POWER]
TEST 12
Graphic equalizer test
CD TEST MODE
• Setting the test mode
Any one of test mode can be set by pressing several keys as follows.
<X-BASS> + <CD> + <POWER> TEST: CD operation test.
Any one of test mode can be set by pressing several keys as follows.
<X-BASS> + <CD> + <POWER> TEST: CD operation test.
Enter test 1 mode key.
C D T E S T
OPEN/CLOSE operation is using manual.
Do TOC IL. Do normal play.
When these following key is input into PLAY key,
track number can be appoint directly.
When these following key is input into PLAY key,
track number can be appoint directly.
<<PLAY>> key input.
<<MEMORY>> key input.
Laser ON.
<<MEMORY>> key input.
Tracking OFF play at that specific point.
<<MEMORY>> key input.
<<
1>> key: Track 1
<<
2>> key: Track 3
<<
3>> key: Track 7
<<
4>> key: Track 11
<<
5>> key: Track 13
<<
6>> key: Track 15
Tracking ON play from that specific point.
<<MEMORY>> key input
a) Display
"FOFF_XX"
b) Display
"TOFF_XX"
c) Display
"TBAL_XX"
d) Display
"TGAN_XX"
e) Display
"FGAN_XX"
f) Display
"RFLS_XX"
<<
>>, <<
>> buttons make pick's slide possible.
<<STOP>> key input.
STOP
<<MEMORY>> key input.
a) Display
"FOFF_XX"
b) Display
"TOFF_XX"
c) Display
"TBAL_XX"
d) Display
"TGAN_XX"
e) Display
"FGAN_XX"
f) Display
"RFLS_XX"
Display every auto setting result for every 2 sec.
<<STOP>> key input.
STOP
VOL
––
Last memory
BAL
––
CENTER
P.GEQ
––
FLAT
X-BASS
––
OFF
Sliding the PICKUP with
<<
<<
>>, <<
>> button
must only be in STOP mode.
Display each step for 2 sec. XX: HEX VALUE
a) "FOFF_XX"
a) "FOFF_XX"
Focus off set
b) "TOFF_XX"
Tracking off set
c) "TBAL_XX"
Tracking balance
d) "TGAN_XX"
Tracking gain
e) "FGAN_XX"
Focus gain
f ) "RFLS_XX"
RF level shift
To cancel : Power OFF