CD-BA250H/CD-BA2600H
– 18 –
Standard Specification of Stereo System Error Message Display Contents
                     Error Contents
DISPLAY
                               Notes
Output while Device Protection Operation.
'PROTECT'
00: While in Protect Circuit Operate.
01: Over Current Detection.
02: DC Detection.
03:
TAPE
Mechanism Error.
'ER-TA**'
00: Tape Mechanism Error.
01: Initial Error.
02:
03:
CD/VCD
Pickup Mechanism Error.
'ER-CD**'
00: Pickup Mechanism Error.
01: PU-IN SW Detection NG.
02:
03:
04:
CD Changer Mechanism Error.
'ER-CD**'
10: Changer Error.
11: Initial Error.
12:
13:
Tray Error.
'ET-CD**'
20: Tray Error.
21:
22:
23:
Focus Not Match.
'NO DISC'
IL Time Over.
'NOT READ'
TUN
PLL Unlock.
'ER-TU**'
00: TUN Error.
01: PLL Unlock.
02:
03: