CD-BA2010 (serv.man8). Part 5 - Voltage table, Troubleshooting tables, IC tables - Sharp Audio Service Manual (repair manual). Page 7

Read Sharp CD-BA2010 (serv.man8) Service Manual online

– 49 –
CD-BA2010H
IC2  VHiLC78641E-1: Servo/Signal Control (LC78641E) (1/2)
1
PDO1
Output
For PULL
Phase-comparison output terminal for built-in VOC control.
2
PDO2
Output
Phase-comparison output terminal for built-in VOC control.
Rough servo : OFF, phase servo : ON.
3
VVSS
Ground terminal for built-in VCO.
4
PCKIST
AI
Resistor terminal for setting  the PDO output current.
5
VVDD
Power terminal for built-in VCO.
6
FR
AI
Resistor terminal for setting  the VCO frequency range.
7
HFL
Input
Mirror detection signal input terminal.
8
SLCIST
AI
For slice level control
Resistance connection terminal for current adjustment of
SLCO output.
9
SLCO
Output
Control output.
10
EFMIN
Input
EFM signal input terminal.
11*
JITTV
Output
Unfixed
Jitter detection/monitor terminal.
12
JITTC
Output
Jitter detection/adjustment terminal.
13
BH
Input
BH signal input terminal. A/D input.
14
PH(RFENV)
Input
PH signal or RFENV signal input terminal. A/D input.
15
FE
Input
FE signal input terminal. A/D input.
16
TE
Input
TE signal input terminal. A/D input.
17
VREF
Input
VREF signal input terminal. A/D input.
18
ADAVDD
AD for servo, D/A power terminal.
19
ADAVSS
AD for servo, D/A ground terminal.
20*
PHREF
Output
(1/2VDD)
PH reference output terminal. D/A output.
21*
BHREF
Output
(1/2VDD)
BH reference output terminal. D/A output.
22
TBLO
Output
(1/2VDD)
Output terminal for tracking balance. D/A output.
23
TDO
Output
(1/2VDD)
Output terminal for tracking control. D/A output.
24
FDO
Output
(1/2VDD)
Output terminal for focus control. D/A output.
25
SPDO
Output
(1/2VDD)
Output terminal for spindle control. D/A output.
26
SLDO
Output
(1/2VDD)
Output terminal for sled control. D/A output.
27*
FG
Input
FG signal input terminal. (When not used, connect to 0V)
28
LASER
Output
L
LASER ON/OFF control terminal.
29
CONT1
In/Output
Input mode
General purpose input/output terminal 1.
Controlled with serial data command
30
CONT2
In/Output
Input mode
General purpose input/output terminal 2.
from microcomputer. When not used,
31
CONT3
In/Output
Input mode
General purpose input/output terminal 3.
set it as the input terminal and
32
CONT4
In/Output
Input mode
General purpose input/output terminal 4.
open it by connecting to 0V, or set it
33
CONT5
In/Output
Input mode
General purpose input/output terminal 5.
as the output terminal and open it.
34*
PCK
Output
H
Clock monitor terminal for EFM data replay. 4.3218 MHz as phase clock.
35*
C2F
Output
H
C2 flag output terminal.
36
VDD
Power terminal of digital system.
37*
DOUT
Output
L
Output terminal of digital OUT. (EIAJ format)
38*
FSX
Output
L
Output terminal of synchronous signal of 7.35 kHz divided from quartz oscillation.
39*
EFLG
Output
L
C1,C2 correct monitor terminal.
40
TEST
Input
Input terminal for test. Surely connected to 0V.
41*
EMPH
In/Output
Input mode
Emphasis terminal. After resetting, it is configured as an input terminal. It can be controlled
from the outside. It is also becomes a emphasis monitor terminal under command control.
42*
MUTEL
Output
H
Mute output terminal for L channel.
43*
MUTER
Output
H
Mute output terminal for R channel.
Pin No.
Function
Terminal Name
Input/Output Setting in Reset
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Page of 12
Display