CD-BA160 (serv.man4). Part 1 - text - Sharp Audio Service Manual (repair manual). Page 15

Read Sharp CD-BA160 (serv.man4) Service Manual online

– 15 –
CD-BA160H/1700H
Any one of test mode can be set by pressing several keys as
fallows.
 <X-BASS> + <CD> + <POWER> TEST:CD operation test
Function:-CD test mode.
               -Enter test mode.
C  D       T  E  S  T
OPEN/CLOSE operation is using manual.
<<
>>, <<
>> buttons make pick's slide possible.
Do TOC IL. Do normal play
When these following key is
input into PLAY key, track
number  can be appoint directly
<<PLAY>> key input.
<<MEMORY>> key input.
<<
1>> key: Track 4
<<
2>> key: Track 9
<<
3>> key: Track 15
<<STOP>> key input.
STOP
Laser ON.
<<MEMORY>> key input.
Tracking OFF play at that
specific point.
<<MEMORY>> key input.
Tracking ON play at that
specific point.
<<STOP>> key input.
STOP
VOL — Last memory
BAL — CENTER
P.GEQ — FLAT
X-BASS — OFF
To cancel : Power OFF
Sliding the PICKUP with
<<
>>, <<
>> button
must only be in STOP mode.
CD SECTION
Figure 15-1
CD ERROR CODE DESCRIPTION
Error
State Code
[Servo System Error]
0001
Cannot detect Pickup-in SW
0002
DSP access error
[Error during close operation]
0101
Open/Close SW Low 
→ 
High not functioning
0103
Open/Close SW High 
 Low not functioning
[Error during open operation]
0201
Open/Close SW Low 
→ 
High not functioning
0203
Open/Close SW High 
 Low not functioning
[Error during skip operation]
0302
Pickup-in SW is not detected
0306
During Disc 1 search, Open/Close SW or Clamp SW
or Disc SW do not change to low.
0307
Clamp SW Low 
→ 
High not functioning
0308
Clamp SW High 
 Low not functioning
Since this CD system incorporates the following automatic
adjustment functions, readjustment is not needed when
replacing the pickup. Therefore, different PWBs and pickups
can be combined freely.
Each time a disc is changed, these adjustments are
performed automatically. Therefore, playback of each disc
can be performed under optimum conditions.
Items adjusted automatically
(1) Offset adjustment (The offset voltage between the head
amplifier output and the VREF reference voltage is
compensated inside the IC.)
  * Focus offset adjustment
  * Tracking offset adjustment
(2) Tracking balance adjustment (waveform drawing 15-1
EFBL)
(3) Gain adjustment (The gain is compensated inside the IC
so that the loop gain at the gain crossover frequency will
be 0dB.)
  * Focus gain adjustment
  * Tracking gain adjustment
 
Adjustment
T
T
EFBL
FDO
TE
Stopped
CH1=500mV
DC   10:1
CH2=200mV
DC   10:1
CH3=1V
DC   10:1
500ms/div
(500ms/div)
NORM:20kS/s
1
2
3
=Record Length=
Smoothing :   ON
CH1  :      0.000V
CH2  :      0.000V
Main  :     100K
Zoom  :       2k
Mode  :   SINGLE
Type   :   EDGE CH1
Delay  :                    0.0ns
Hold off  :                0.2us
CH3  :        0.00V
CH4  :        0.00V
BW   : FULL
=Trigger=
=Filter=
=Offset=
CH2
  v/DIV
   200mV
1999/04/05  20:26:47
IL isn't done
 
Setting the test mode
TEST MODE
Page of 19
Display

Click on the first or last page to see other CD-BA160 (serv.man4) service manuals if exist.