CHAPTER 2. ADJUSTMENTS
[1] Description Of Error Messages
* For other error messages using STANDBY LED, refer to the corresponding pages.
Error message
Cause
Solution
“ERR 01”
(Appears for 2 seconds and then the system
goes standby.)
(Appears for 2 seconds and then the system
goes standby.)
• Rotation stop of the fan motor
• Check if the fan motor cord is inserted
properly and the fan motor is not locked.
“ERR 02”
(When this error is not detected, the initial
display appears.)
(When this error is not detected, the initial
display appears.)
• Error in the ICM6 (CS49510) control
• Unplug the AC power cord and turn on
power again.
• Check the line connected between ICM6
and ICM7.
“ERR 03”
(When this error is not detected, the initial
display appears.)
(When this error is not detected, the initial
display appears.)
• Internal communication error of the system
[ICA1 (WM8775) or ICM3 (CS8416CN)]
• Unplug the AC power cord and turn on
power again.
• Check the line connected among ICA1,
ICM3, ICM8 and ICM7.
“ERR 07”
(When this error is not detected, the initial
display appears.)
(When this error is not detected, the initial
display appears.)
• Internal communication error of the system
[ICM10 (LC750512)]
• Unplug the AC power cord and turn on
power again.
• Check the line connected between ICM10
and ICM7.
“ERR 80”
(When this error is not detected, the initial
display appears.)
(When this error is not detected, the initial
display appears.)
• Internal data read access error of ICM8
(CAT24WC05YI)
• Check EEPROM data.
• Replace EEPROM IC (ICM8).
• Replace EEPROM IC (ICM8).