GS-XR217 - Sharp Air Conditioner Service Manual (repair manual). Page 11

Read Sharp GS-XR217 Service Manual online

33
ENGLISH
CN
Connector
CNR
RC filter
CP
Compressor
CT
Current transformer
DB1
Diode bridge
DB2
Diode bridge
FC
Fan motor capacitor
FM
Fan motor
WPE
Fuse
IM
Magnetothermic switch
LM
Louvre motor
NR
Varistor
PE
Ground connection
PM1
Power transistor module
PTC
Variable resistor
RY
Relay
MRY
Relay
TB
Terminal board
TH 1
Room sensor (indoor unit)
TH 1
Compressor sensor (outdoor unit)
TH 2
Heat exchanger sensor
TH 3
Outdoor temperatur sensor
TH 4
Suction sensor
TR
Transformer
UE
Outdoor unit
UI
Indoor unit
VI
Reverse cycle valve
Field wiring
Components not supplied
WIRING DIAGRAMS LEGEND
BL
= Blue
G
=
Gray
GV
= Yellow-Green
MA
= Brown
NE
= Black
GI
= Yellow
RO
= Red
BI 
= White
AR
= Orange
VE
= Green
INTERMEDIATE SPEED CORRECTION FACTORS
TAB.  A
Mod.
Max. Speed
Med. Speed
Min. Speed
Cooling
1
0,97
0,93
Heating
1
0,95
0,87
REFRIGERANT CONNECTION
TAB.  B
Mod.
GS-XC077E
GS-XC107E
GS-XC157E
GS-XC217E
GS-XR077E
GS-XR107E
GS-XR157E
GS-XR217E
LG
Ø
9,52 x 0,75  (
3
/
8
”)
12,7 x 0,81  (
1
/
2
”)
12,7 x 0,81  (
1
/
2
”)
15,88 x 0,81  (
5
/
8
”)
LL
Ø
6,35 x 0,71  (
1
/
4
”)
6,35 x 0,71  (
1
/
4
”)
6,35 x 0,71  (
1
/
4
”)
6,35 x 0,71  (
1
/
4
”)
LG
= gas line.
LL
= liquid line.
The refrigerant lines must have a maximum lenght of 15 metres (20 for GS-XC217E - GS-XR217E). If the lenght exceeds 10 metres
(15 for GS-XC217E - GS-XR217E), 20g of refrigerant must be added for each metre of line.
The height difference between indoor and outdoor unit must not exceed 5 metres.
ELECTRICAL DATA
TAB.  C
Mod.
GS-XC077E
GS-XC107E
GS-XC157E
GS-XC217E
GS-XR077E
GS-XR107E
GS-XR157E
GS-XR217E
SEZ. A
Ø 
( mm
2
)
1,5
1,5
2,5
4
IM
A
10
10
16
20
Page of 18
Display