AY-XP13CR (serv.man4). Wiring diagrams - Sharp Air Conditioner Service Manual (repair manual)

ay-xp13cr (serv.man4) service manual
Model
AY-XP13CR (serv.man4)
Pages
4 Few pages! See other manuals at the bottom of the first or last page.
Size
582.92 KB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / Wiring diagrams
File
ay-xp13cr-sm4.pdf
Date

Read Sharp AY-XP13CR (serv.man4) Service Manual online

5
AY-XP08CR
AY-XP10CR
AY-XP13CR
Figure W-1. Wiring Diagram for AY-XP08CR / AY-XP10CR  / AY-XP13CR
WIRING DIAGRAMS
2.5 or 3A
400 or 430 or 450V
6
AY-XP08CR
AY-XP10CR
AY-XP13CR
Figure W-2. Wiring Diagram for AE-X08CR / AE-X10CR
+
-
+
-
N
1
2
INDOOR UNIT
TERMINAL
BOARD
CONTROL
BOARD
UNIT
POWER
SUPPLY
FAN
MOTOR
TERMINAL BOARD
UNIT TO UNIT CORD
SINGLE PHASE
220-240V 50Hz
BL
T2
BR
T3
RE
FC4
BULK HEAD
RE
T1
WPE1
C1
C2
C3
C4
C33
C34
15A
250V
SA1
RY1
T4
BCN11
CT1
The voltage is high at C8 (electronic capacitors) on outdoor unit.
For mentenance discharge at C8 to prevent electric shock.
In case that WPE101 has been fused, the voltage is kept high at C8.
CAUTION
BK
:BLACK          
RE
:RED                     YE
:YELLOW
BL
:BLUE             WH
:WHITE                G:GREEN
BR
:BROWN         
OR
:ORANGE
GR
:GRAY            G
(Y
):
GREEN
-YELLOW
BL
GR
G
(Y
)
G
(Y
)
FAN
MOTOR
BL
PTC
MRY1
IN
OUT
T6
T5
BK
TP
TN
YE
C8
OUTDOOR UNIT
POWER
TRANSISTOR
MODULE  
(QM101
)
TU
TV
TW
RE
WH
OR
COMPRESSOR
THERMISTOR
PIPE TEMP.
THERMISTOR
OUTDOOR
TEMP.
THERMISTOR
COMP. TEMP.
CN8
TH2
TH1
TH3
RE
OR
G
3
1
5
LED INDICATION OF SELF-DIAGNOSIS
ON OUTDOOR UNIT
LED BLINKING
LED turns on
Slow flashing 
(1 time for 2 seconds
)
Quick flashing 
(3 times for 2 seconds
)
Example: NO.2  Overheat of the compressor
1.0sec
0.6sec
0.6sec
1.0sec
0.6sec
0.6sec
CB565
1
2
3
4
10
NO.
LED indication pattern
Mulfunction part or abnormal condition
Normal
Abnormal signal line
Overheat of the compressor
DC overcurrent of the power module 
(QM101
Short circuit of the thermistor
7
8
6
NO.
LED indication pattern
Mulfunction part or abnormal condition
Open circuit of the thermistor
AC overcurrent
AC abnormal current
BK
1
2
3
4
5
6
NR1
NR2
CNR1
N
1
2
L3
L4
WPE3
3A
250V
CN3
CONTROL BOARD UNIT
DIODE BRIDGE
DB1
BL
C5
WPE101
20A
250V
OR
FC1
C10
C
AM
CONTROL
BOX
FAN MOTOR
CAPACITOR
1.5
µF 450V
C31
+
-
L1
WH
C8:1000
µF  420V
BL
~
~
9
Power factor module(AF1) error
S
R
C(T)
FC5
AF1
L-
L+
I-
I+
ACTIVE
FILTER
O-
O+
WH
YE
BR
FC2
3
1
RY2
CNR2
4-WAY
VALVE
5
11
Overheat of the power module or
short circuit of the heat-sink thermistor
Open circuit of the heat-sink thermistor
Rotation error of the compressor
C36
C35
C37
C38
BK
1
3
THERMISTOR
HEAT-SINK
TEMP.
CN7
4
1
YE
BL
CN12
CN13
BCN2
CN101
CN102
CN6
2
4
6
RE
WH
OR
POWER
TRANSISTOR
 UNIT
NO.3  DC overcurrent of the power module 
(QM101
1.0sec
0.6sec
0.6sec
1.0sec
0.6sec
0.6sec
0.6sec
0.6sec
x 2times
x 3times
x 4times
x 5times
x 6times
x 7times
x 9times
x 11times
x 13times
x 14times
CN4
7
AY-XP08CR
AY-XP10CR
AY-XP13CR
Figure W-3. Wiring Diagram for AE-X13CR
+
-
+
-
N
1
2
INDOOR UNIT
TERMINAL
BOARD
CONTROL
BOARD
UNIT
POWER
SUPPLY
FAN
MOTOR
TERMINAL BOARD
UNIT TO UNIT CORD
SINGLE PHASE
220-240V 50Hz
BL
T2
BR
T3
RE
FC4
BULK HEAD
RE
T1
WPE1
C1
C2
C3
C4
C33
C34
20A
250V
SA1
RY1
T4
BCN11
CT1
The voltage is high at C8 (electronic capacitors) on outdoor unit.
For mentenance discharge at C8 to prevent electric shock.
In case that WPE101 has been fused, the voltage is kept high at C8.
CAUTION
BK
:BLACK          
RE
:RED                     YE
:YELLOW
BL
:BLUE             WH
:WHITE                G:GREEN
BR
:BROWN         
OR
:ORANGE
GR
:GRAY            G
(Y
):
GREEN
-YELLOW
BL
GR
G
(Y
)
G
(Y
)
FAN
MOTOR
BL
PTC
MRY1
IN
OUT
T6
T5
BK
TP
TN
YE
C8
OUTDOOR UNIT
POWER
TRANSISTOR
MODULE  
(QM101
)
TU
TV
TW
RE
WH
OR
COMPRESSOR
THERMISTOR
PIPE TEMP.
THERMISTOR
OUTDOOR
TEMP.
THERMISTOR
COMP. TEMP.
CN8
TH2
TH1
TH3
RE
OR
G
3
1
5
LED INDICATION OF SELF-DIAGNOSIS
ON OUTDOOR UNIT
LED BLINKING
LED turns on
Slow flashing 
(1 time for 2 seconds
)
Quick flashing 
(3 times for 2 seconds
)
Example: NO.2  Overheat of the compressor
1.0sec
0.6sec
0.6sec
1.0sec
0.6sec
0.6sec
CB566
1
2
3
4
10
NO.
LED indication pattern
Mulfunction part or abnormal condition
Normal
Abnormal signal line
Overheat of the compressor
DC overcurrent of the power module 
(QM101
Short circuit of the thermistor
7
8
6
NO.
LED indication pattern
Mulfunction part or abnormal condition
Open circuit of the thermistor
AC overcurrent
AC abnormal current
BK
1
2
3
4
5
6
NR1
NR2
CNR1
N
1
2
L3
L4
WPE3
3A
250V
CN3
CONTROL BOARD UNIT
DIODE BRIDGE
DB1
BL
C5
WPE101
20A
250V
OR
FC1
C10
C
AM
CONTROL
BOX
FAN MOTOR
CAPACITOR
2.0
µF 450V
C31
+
-
L1
WH
C8:1300
µ
F  420V
BL
~
~
9
Power factor module(AF1) error
S
R
C(T)
FC5
AF1
L
-
L
+
I
-
I
+
ACTIVE
FILTER
O
-
O
+
WH
YE
BR
FC2
3
1
RY2
CNR2
4-WAY
VALVE
5
11
Overheat of the power module or
short circuit of the heat-sink thermistor
Open circuit of the heat-sink thermistor
Rotation error of the compressor
C36
C35
C37
C38
BK
1
3
THERMISTOR
HEAT-SINK
TEMP.
CN7
4
1
YE
BL
CN12
CN13
BCN2
CN101
CN102
CN6
2
4
6
RE
WH
OR
POWER
TRANSISTOR
 UNIT
NO.3  DC overcurrent of the power module 
(QM101
1.0sec
0.6sec
0.6sec
1.0sec
0.6sec
0.6sec
0.6sec
0.6sec
x 2times
x 3times
x 4times
x 5times
x 6times
x 7times
x 9times
x 11times
x 13times
x 14times
CN4
8
AY-XP08CR
AY-XP10CR
AY-XP13CR
For Model AY-XP08CR / AY-XP10CR / AY-XP13CR
DESCRIPTION
MODEL
REMARKS
Indoor fan motor
MLA915
220 - 240V, 50Hz
Indoor fan motor capacitor
400V or 430V or 450V, 2µF
Transformer
Primary; AC 220 - 240V, 50Hz
Secondary; AC19V, 50Hz
WPE1
QFS-GA040JBZZ (250V, 3A)
For Model AE-X08CR /  AE-X10CR
Compressor
DA89X1F
D.C. brush-less motor
Outdoor fan motor
MLA902
220 - 240V, 50Hz   220V, 60Hz
Outdoor fan motor capacitor
430V or 450V, 1.5µF
WPE1
QFS-GA033JBZZ(15A, 250V)
WPE101
QFS-GA019JBE0(20A, 250V)
WPE3
QFS-GA008JBE0(3A, 250V)
or QFS-GA040JBZZ (3A, 250V)
WPE5
QFS-GA037JBZZ(1A, 250V)
For Model AE-X13CR
Compressor
DA89X1F
D.C. brush-less motor
Outdoor fan motor
MLA903
220 - 240V, 50Hz   220V, 60Hz
Outdoor fan motor capacitor
430V or 450V, 2.0µF
WPE1
QFS-GA014JBE0(20A, 250V)
WPE101
QFS-GA019JBE0(20A, 250V)
WPE3
QFS-GA040JBZZ(3A, 250V)
WPE5
QFS-GA037JBZZ(1A, 250V)
ELECTRICAL PARTS
Page of 4
Display

Download Sharp AY-XP13CR (serv.man4) Service Manual (Repair Manual)

Here you can read online and download Sharp AY-XP13CR (serv.man4) Service Manual in PDF. AY-XP13CR (serv.man4) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AY-XP13CR (serv.man4) Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.