AY-XP10CR (serv.man10). Breakdown diagnosis procedure - Sharp Air Conditioner Service Manual (repair manual). Page 2

Read Sharp AY-XP10CR (serv.man10) Service Manual online

29
AY-XP08CR
AY-XP10CR
AY-XP13CR
Note:
1.
Normal : Only the timer lamp blinks.
Error : Displayed by blinking of run lamp (above table).
2.
If the power plug is removed from the outlet or the breaker is switched to
               "OFF", the self-diagnostic memory will be erased.
3.
Example of outdoor unit LED 1 blinking :
: Blinks at 2-second intervals
: OFF
: ON
: Blinks 3 times at 0.2-second intervals
Indoor unit 
operating
Outdoor unit 
completely stopped
Only recall of self-diagnosis 
memory.
Indoor and outdoor units are 
not stopped.
Display by indoor unit operation lamp
Displayed in a pattern which comes on at  the same 
time as the timer lamp
4 seconds off
What to check, procedure
Display by 
outdoor 
unit lamp 
LED 1
Diagnosis
Solution
Condition 
of indoor 
and 
outdoor 
unit
Serial short
Serial open
Cluster generator 
circuit error
1. Check the wiring between units.
1. Check the wiring between units.
1. Check the wiring between units.
2. Check the fuse in the outdoor unit.
3. Indoor control board.
4. Outdoor control board.
1. Check the wiring between parts.
2  Indoor control board.
3. Hi-voltage unit.
1. Rewire.
2  Replace the control board.
3. Replace the Hi-voltage unit.
1. Rewire.
1. Rewire.
Indoor fan out of order
1. Is the fan motor locked ?
2. Is the wiring connector firmly fitted ?
3. Is the rotation pulse signal applied to the motor ?
Outdoor power supply  
does't turn on.
Wiring mistake.
1. Rewire.
2. Replace the fuse, replace the 
outdoor board assembly.
3. Replace the control board.
4. Replace the control board.
1. Replace fan motor
2. Reattach.
3. Replace the indoor control board 
assembly.
1
sec..
1
sec
0.6
sec.
1
sec.
1
sec.
1
sec.
1
sec.
1
sec.
0.6
sec.
1
sec.
1
sec.
1
sec.
1
sec.
1
sec.
1
sec.
Compressor  lock
1
sec.
1
sec.
1
sec.
Overheat of the compressor
0.6
sec.
0.6
sec.
1
sec.
0.6
sec.
1
sec.
0.6
sec.
1 time
2 times
ON
OFF
ON
OFF
Page of 3
Display

Click on the first or last page to see other AY-XP10CR (serv.man10) service manuals if exist.