AY-X13 (serv.man16) - Sharp Air Conditioner Service Manual (repair manual). Page 27

Read Sharp AY-X13 (serv.man16) Service Manual online

27
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
BREAK DO
WN DIA
GNOSIS PR
OCEDURE
Self-diagnostic procedure using display mode
If the timer lamp blinks during operation, the problem can be diagnosed using the following table.
: Blinks at 2-second intervals
: OFF
: ON
: Blinks 3 times at 0.2-second intervals
The error of outdoor unit
Display by indoor unit operation lamp
Displayed in a pattern which comes on at  the same 
time as the timer lamp
4 seconds off
What to check, procedure
Display by 
outdoor 
unit lamp 
LED 1
Diagnosis
Solution
Condition 
of indoor 
and 
outdoor 
unit
Normal
Twice
3 times
4 times
5 times
6 times
7 times
DC overcurrent error
AC overcurrent error
Normal
Overheat of the power
module or short circuit
of the heatsink 
thermistor.
1. Check the circuit in the power transistor module.
2. Is the outdoor fan revolving ?
1. Is the discharge outlet of the outdoor unit clogged ?
1. Measure the resistance of heatsink thermistor TH6 on the heatsink 
    in outdoor unit.
2. Check rotation of the fan motor in outdoor unit.
3. Is the power supply voltage at least 198V at full power operation ?
1. Measure the resistance of thermistor TH2 on the outdoor unit
    (see Figure 3).
1. Replace power transistor 
module
1. Clear the discharge outlet.
11 times
Power factor module error
1. CHeck wiring of power factor module.
1. Replace the power factor module.
1. Reattach.
2. Reattach CN101 and CN102, 
    otherwise replace power transistor 
    module assembly or outdoor control 
    board assembly.
9 times
14 times
13 times
Rotation errot of the 
compressor
1. Has not if escaped from the compressor CN6 ?
2. Is the power supplied of 15V and 6V supplied to the IPM PWB.
1. Replace the heatsink thermistor.
Open circuit of the 
heatsink thermistor.
1. Are the connectors of the heatsink thermistor in outdoor unit well 
    attached ?
2. Measure the resistance of thermistor TH6 on the heatsink. 
    (See Figure 3).
Overheat of the comp-
ressor error
(protector operating) or 
outdoor compressor  
thermistor TH1 short
1. Reattach.
2. Replace the heatsink thermistor.
1.
Replace the outdoor control board 
assembly 
(Current transformer wire break.) 
1. Reattach.
2.
Replace the outdoor thermistor 
assembly.
1.
Replace the outdoor thermistor 
assembly.
1.
Clear the discharge outlet.
2.
Assure power supply voltage.
3.
Refill to rated amount.
4.
Replace the outdoor ther-mistor 
assembly.
5.
Replace the indoor control 
board 
assembly or only TH2.
1. Can voltage be detected at the current transformer on the outdoor 
unit control board?
1.  Is the connector of the outdoor unit thermistors well attached ?
     (see Figure 3).
2. Measure the resistance of thermistors TH1 and TH2 on the 
outdoor unit (see Figure 3).
1. Is the discharge outlet of the outdoor unit clogged ?
2. Is the power supply voltage at least 198 V at full power operation ?
3. Check for refrigerant leaks at the tubing connections.
4. Measure the resistance of compressor thermistor TH1 on the 
outdoor unit (see Figure 3).
5. Measure the resistance of heat exchanger pipe thermistor TH2 on 
the indoor unit (see Figure 1).
AC abnormal current  
error
Open circuit of the 
outdoor thermistor error
Short circuit of the  
outdoor thermistor error
2.
Reattach CN3, otherwise replace 
    the fan motor of outdoor unit.
    3. Assure power supply voltage.
Page of 60
Display

Click on the first or last page to see other AY-X13 (serv.man16) service manuals if exist.