AY-X127E - Sharp Air Conditioner Service Manual (repair manual). Page 2

Read Sharp AY-X127E Service Manual online

AH-X127E
AU-X127E
AY-X127E
AE-X127E
2
SPECIFICATIONS
Models
INDOOR UNIT
OUTDOOR UNIT
AH-X127E
AU-X127E
Cooling capacitor
kW
3.5 (1.4 
 3.8)
Moisture removal
Liters/h
1.3
Electrical data
Phase
-
Single
Rared frequency
Hz
50
Rated voltage range
V
198 to 264
Rated voltage
V
220 - 240
Rated current
A
7.9 - 7.5
Rated input
W
1650
Power factor
%
95 - 92
Compressor
Type
Hermetically sealed rotary type
Model
KHV127FEM
Oil charge
270cc(SUNISO 4GSD)
Refrigerant
Evaporator
Grooved tube type
system
Condenser
Corrugate Fin and Grooved tube type
Control
Capillary tube
Refrigerant volume
720g
Noise level
High
dB(A)
41
49
(at cooling)
Med.
dB(A)
37
-
Low
dB(A)
33
-
Fan system
Drive
Direct drive
Air flow
High
m
3
/min.
9.8
28.3
quantity
Med.
m
3
/min.
8.5
-
(at cooling)
Low
m
3
/min.
7.0
-
Fan
Close flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
1/2", 1/4"
Refrigerant pipe sets No.
AZ-24H5E; 5m (16.4 ft), AZ-24H7E; 7m (23ft)
Drain pipng mm (Inches)
O.D ø 18 (45/64)
Others
Safety device
Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filter
Polypropylene net (Washable)
Net
Width
mm
790 (31-3/32)
728 (28-21/32)
dimensions
Height
mm
270 (10-5/8)
530 (20-7/8)
Depth
mm
188 (7-13/32)
250 (9-27/32)
Net weight
kg
8
33
Note: The condition of star( ) marked item are 'IEC 378'.