27
AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
AY-AP24CS
AE-A18CS
AE-A24CS
DISASSEMBLING PROCEDURE
FOR INDOOR UNIT MODEL [AY-AP18CS / AY-AP24CS]
CAUTION:DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY SERVICING
1.
Open the Opne panel, remove 2 Air Filters.
2.
Open the Louver frame.unlook the hooks,and pull
the unit.
the unit.
3.
Remove 6 screws fixing the Front panel.
4.
Remove the screw fixing the Cord holder.
AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
AY-AP24CS
AE-A18CS
AE-A24CS
28
5.
Close the Open panel. pushing the nail of the
Front panel, and lift the Front panel up.
Front panel, and lift the Front panel up.
6.
Remove the unit-to-unit wiring from the Terminal
board.
board.
7.
Remove a screw fixing the Control box cover.
8.
Cut the fixing band and Remove the Cover B.
9.
Remove a screw fixing the ground wire.
29
AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
AY-AP24CS
AE-A18CS
AE-A24CS
10.
Remove the Thermistor of the Evaporator.
11.
Remove Connectors.
12.
Cut the fixing band and Remove the Holder.
13.
Remove 2 screws fixing the Control box and
remove it.
remove it.
AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
AY-AP24CS
AE-A18CS
AE-A24CS
30
14.
Remove a screw fixing the drain pan and pull
Drain pan toward you.
Drain pan toward you.
15.
Remove the Drain cover from the Evaporator.
16.
Remove 3 screws fixing the Evaporator.
17.
Remove the Evaporator from the Cabinet.
18.
Remove 4 screws fixing the Side cover R, and
pull up the Cross flow fan.
pull up the Cross flow fan.
19.
Loose a screw fixing Cross flow fan.