AY-AP18 (serv.man9). Refridgeration cycle - Sharp Air Conditioner Service Manual (repair manual). Page 2

Read Sharp AY-AP18 (serv.man9) Service Manual online

AY-AP18CS
AY-AP24CS
AE-A18CS
AE-A24CS
24
Cycle temperature and service port pressure
SASO 385 condition
Dimension of Capillary tube
O.D.
I.D.
L
Capillary tube A
ø 3.2
ø 2.0
500
Capillary tube C
(Upper  row)
  
ø 2.7
ø 1.6
150
Capillary tube D
(Lower  row)
  
ø 2.7
ø 1.6
244
O.D.
I.D.
L
Capillary tube A
ø 3.5
ø 2.4
600
Capillary tube B
ø 3.5
ø 2.4
400
Capillary tube C
(2 pieces)
ø 3.6
ø 1.8
100
For AY-AP18CS
For AY-AP24CS
Indoor side
Outdoor side
Temperature (˚C)
Temperature (˚C)
Relative humididity (%)
Relative humididity (%)
29
39
46
15
Cooling
21
-
7
87
Heating
Cooling
Heating
NO. Condition
Model
AY-AP18CS
1
2
3
4
Service port pressure
100˚C
81C
56˚C
2˚C
15˚C
41˚C
4˚C
0.51MPa
1.73MPa
Cooling
Heating
AY-AP24CS
97˚C
88˚C
54˚C
31˚C
14˚C
45˚C
4˚C
-2˚C
-3˚C
0.51MPa
1.80MPa
Based on 'SASO 385 / 1983'
(at 220V refrigerant pipes length 7.5m)
Page of 2
Display