AY-A244 - Sharp Air Conditioner Specification (repair manual). Page 12

Read Sharp AY-A244 Specification online

12
AY-A184E
AY-A244E
AE-A184E
AE-A244E
2-3
Heat operation
The compressor turns off, at State  2  , turns on
continuously at State  1  &  3 .
Figure Y-6
2-4
Fan only operation
The indoor fan motor always turns on.
3. Fan speed
Fan speeds are given by the indoor fan motor, “M”,
“L” and “UL”, which are available in the following
operation mode.
Table Y-2
FAN Switch
HEAT
COOL      FAN ONLY
    HIGH
M
M
        M
    LOW
L
L
         L
    SOFT
UL
UL
       UL
Figure Y-5
Table Y-1
Compressor
Fan Speed
Cooling zone
ON
“UL”
Dehumidifying
ON
“D”
zone
Circulating
OFF
“D” or OFF
zone
2-2
DRY operation
 On the switch on, the compressor always starts to
operate for 2 minutes with fan speed “D” (slower
than “UL”).
The microcomputer reads the room temperature 2
minutes after this first compressor operation.
This room temperature is set as the preset
temperature automatically.
The preset temperature ranges from 18˚C to 32˚C.
When the room temperature is below 18˚C, the
preset temperature is  set to 18˚C, and when the
room temperature is over 32˚C, the preset
temperature is set to 32˚C.
Dry operation is divided into three zones (Cooling
zone, Dehumidifying zone and Circulating zone)
by thermostat lines (D1 to D3), and the compressor
and the fan motor are controlled in each zone as
shown in Table Y-1.
Room temperature
Preset temperature
Room 
temperature 
transition
D3
D2
D1
States 1 & 5 : Cooling zone
States 2 & 4 : Dehumidifying zone
States 3 : Circulating zone
3
4
5
1
2
Room temperature
Preset temperature
Room temperature transition 
H2
H1
States 1 & 3 : Compressor ON
State 2 : Compressor OFF
3
1
2
Page of 44