AY-A07B - Sharp Air Conditioner Service Manual (repair manual). Page 3

Read Sharp AY-A07B Service Manual online

AH-A07BE/09BE/12BE
AY-A07BE/09BE/12BE
AU-A07BE/09BE/12BE
AE-A07BE/09BE/12BE
3
ITEMS
INDOOR UNIT
OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT
INDOOR UNIT OUTDOOR UNIT
AH-A07BE AU-A07BE AH-A09BE AU-A09BE AH-A12BE AU-A12BE
Cooling capacity
kW
2.1
2.64
3.5
Moisture removal
Liters/h
0.7
0.8
1.2
 Electrical data
Phase
Single
Rated frequency
Hz
50
Rated voltage range
V
198 to 264
Rated voltage
V
220 - 240
Rated current 
A
3.1 - 3.0
3.8 - 3.6
5.0 - 4.8
Rated input 
W
650 - 690
820 - 850
1190 - 1120
Power factor 
%
95 - 96
98 - 98
99 - 97
Compressor
Type
Hermetically sealed rotary type
Model
QK134PA13A
QK164PA13A
RH207VHET
Oil charge
300cc (SUNISO 4GSI)
300cc (SUNISO 4GSI)
520cc (DIAMOND MS 56)
Refrigerant system
Evaporator
Louver fin and Bare tube type Louver fin and Grooved tube type
Condenser
Louver fin and Bare tube type Louver fin and Grooved tube type
Control
Capillary tube
Refrigerant volume
480g
550g
870g
Noise level
High
dB(A)
33
43
36
43
38
48
(at cooling)
Med.
dB(A)
29
32
33
Low
dB(A)
27
27
29
Fan system
Drive
Direct drive
Air flow quantity
High
m
3
/min.
7.2
20
8.6
28
9.0
30.0
Med.
m
3
/min.
6.0
6.8
8.1
Low
m
3
/min.
4.8
5.3
7.0
Fan
Cross flow fan
Propeller fan
Cross flow fan
Propeller fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
3/8", 1/4"
1/2", 1/4"
Drain piping
mm
O.D ø 18
Others
Safety device
Compressor: Overload protector
Compressor: Overload protector
                      (Internal)
Fan motor: Thermal fuse
Fuse, Micro computer control
Air filters
Polypropylene net (Washable)
Net dimensions
Width
mm
815
720
815
780
815
780
Height
mm
278
535
278
540
278
540
Depth
mm
198
236
198
269
198
269
Net weight
kg
9
29
9
33
10
38
Note: The condition of star( 
 
 ) marked item are 'ISO5151' : 1994(E), condition T1.