32
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
PERFORMANCE CURVES
NOTE: 1) Indoor fan speed: Hi
2) Vertical adjustment louver "45˚", Horizontal adjustment louver "front"
3) Indoor air temp. : Cooling 27˚C, Heating 20˚C
Figure P-1. At Cooling for AH-X08CR
Figure P-2. At Cooling for AH-X10CR
Figure P-3. At Cooling for AH-X13CR
Figure P-4. At Cooling for AY-X08CR
Figure P-5. At Cooling for AY-X10CR
Figure P-6. At Cooling for AY-X13CR
25
30
35
40
2.0
2.2
2.4
2.6
10
12
14
600
700
800
900
Cooling capacity(kW)
Outside air temp.(˚C)  
Input(W)
Outlet air temp.(
˚C)
(Running frequency: 50HZ)
25
30
35
40
2.4
2.6
2.8
3.0
3.2
12
14
16
700
800
900
1000
(Running frequency: 62Hz)
Cooling capacity(kW)
Outside air temp.(˚C)  
Input(W)
Outlet air temp.(
˚C)
25
30
35
40
3.2
3.4
3.6
3.8
4.0
10
12
14
1000
1100
1200
1300
(Running frequency: 81Hz)
Cooling capacity(kW)
Outside air temp.(˚C)  
Input(W)
Outlet air temp.(
˚C)
25
30
35
40
2.0
2.2
2.4
2.6
10
12
14
600
700
800
900
Cooling capacity(kW)
Outside air temp.(˚C)  
Input(W)
Outlet air temp.(
˚C)
(Running frequency: 51Hz)
25
30
35
40
2.4
2.6
2.8
3.0
3.2
12
14
16
700
800
900
1000
(Running frequency: 63Hz)
Cooling capacity(kW)
Outside air temp.(˚C)  
Input(W)
Outlet air temp.(
˚C)
25
30
35
40
3.2
3.4
3.6
3.8
4.0
10
12
14
1000
1100
1200
1300
(Running frequency: 83Hz)
Cooling capacity(kW)
Outside air temp.(˚C)  
Input(W)
Outlet air temp.(
˚C)
33
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
Figure P-7. At Heating for AY-X08CR
Figure P-8. At Heating for AY-X10CR
Figure P-9. At Heating for AY-X13CR
-5
0
7
5
10
2.4
2.8
3.2
3.6
35
40
45
700
800
900
1000
(Running frequency: 68Hz)
Heating capacity(kW)
Outside air temp.(˚C)  
Input(W)
Outlet air temp.(
˚C)
-5
0
5
7
10
2.5
3.0
3.5
4.0
30
35
40
45
800
900
1000
1100
(Running frequency: 79Hz)
Heating capacity(kW)
Outside air temp.(˚C)  
Input(W)
Outlet air temp.(
˚C)
-5
0
5
7
10
3.0
3.5
4.0
4.5
5.0
5.5
30
35
40
45
1200
1300
1400
1500
1600
(Running frequency: 96Hz)
Heating capacity(kW)
Outside air temp.(˚C)  
Input(W)
Outlet air temp.(
˚C)
Page of 2
Display

Download Sharp AU-X10 (serv.man12) Service Manual (Repair Manual)

Here you can read online and download Sharp AU-X10 (serv.man12) Service Manual in PDF. AU-X10 (serv.man12) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AU-X10 (serv.man12) Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.