AH-X08 (serv.man16) - Sharp Air Conditioner Service Manual (repair manual). Page 2

Read Sharp AH-X08 (serv.man16) Service Manual online

2
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
SPECIFICATIONS
MODEL
INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT
      ITEMS
AH-X08CR AU-X08CR AH-X10CR AU-X10CR AH-X13CR AU-X13CR
Cooling capacity(Min. ~ Max.) kW
2.2(0.9 _ 2.7)
2.8(0.9 _ 3.3)
3.6(0.9 _ 4.0)
Moisture removal
Liters/h
0.6
0.7
1.3
Electrical data
Phase
Single
Rated frequency
Hz
50
Rated voltage range
V
198 to 264
Rated voltage
V
220 - 240
Rated current 
A
3.4 _ 3.1
4.3 _ 4.0
5.5 _ 5.1
Rated input 
W
730
930
1200
Power factor 
%
98 _ 98
98 _ 97
99 _ 98
Type
Hermetically sealed rotary type
Compressor
Model
DA89X1F-20F
Oil charge
Ester oil VG68 370ml
Evaporator
Bare tube type
Grooved tube type
Grooved tube type
Refrigerant system Condenser
Louver Fin and Grooved tube type
Control
Capillary tube
Refrigerant volume
640g
690g
660g
(R-410A)
Noise level
High
dB(A)
33
43
36
43
38
48
(at cooling)
Med.
dB(A)
29
32
33
-
Low
dB(A)
27
27
29
-
Fan system
Drive
Direct drive
Air flow quantity
High
m
3
/min.
7.5
28
8.7
28
9.3
30
 (at cooling)
Med.
m
3
/min.
6.8
7.8
8.1
Low
m
3
/min.
6.0
6.0
6.6
Fan
Cross flow fan Propeller fan Cross flow fan Propeller fan Cross flow fan Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
3/8", 1/4"
Drain piping mm
O.D  ø 18
Others
Compressor: Compressor thermistor
Safety device
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters
Polypropylene net (Washable)
Width
mm
815
780
815
780
815
780
Net dimensions
Height
mm
278
540
278
540
278
540
Depth
mm
198
269
198
269
198
269
Net weight
kg
9
30
9
30
10
33
 Note: The condition of star " " marked item are ‘ISO5151’ : 1994(E), condition T1.