AIR2003 09 01
Month of Issue:  September 2003
        
Classification: 
White
TECHNICAL BULLETIN
Page 1 of 1
Sharp Electronics (UK) Limited
Reference – EHH168
Revision 2
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
 Red – Carry out on all units
MODELS
AHA07
AHA09
AHA12
AHAP18
AHAP24
AHX08
AHX10
AHX13
AYA07
AYA09
AYA12
AYAP18
AYAP24
AYX08
AYX10
AYX13
SYMPTOM No operation of the remote control.
CAUSE
Damaged photo detector.
ACTION
Replace photo detector unit.
REF NO
DESCRIPTION
NEW PART NUMBER
PRICE CODE
-
Photo detector unit
RRMCUA001JBZZ
AK
Discrimination by marking;
Display

Download Sharp AH-A12 (serv.man3) Technical Bulletin

Here you can read online and download Sharp AH-A12 (serv.man3) Technical Bulletin in PDF. AH-A12 (serv.man3) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AH-A12 (serv.man3) Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.