AE-XM24CR (serv.man9). Function and operation of protective procedures - Sharp Air Conditioner Service Manual (repair manual). Page 2

Read Sharp AE-XM24CR (serv.man9) Service Manual online

42
AY-XM7/9/12CR
AY-XPM7/9/12CR
AE-XM18/24CR
8
9
10
11
12
Compressor ia stopped, if heat 
exchanger or outdoor thermistor 
shorts.
Close the expansion valve of the 
corresponding room, if some 
suction thermistor shorts.
Compressor is stopped, if 
compressor or heat exchanger or 
outdoor thermistor opens. 
Close the expansion valve of the 
corresponding room, if some 
suction thermistor shorts. opens. 
Compressor is stopped, if the 
operating frequency is above 70Hz 
and the compressor current is 
below 0.8A.
INDOOR
If open, while timer LED blinks, 
operation is continued.
If short, operation is continued.
OUTDOOR
Closes the expansion valve of the 
corresponding room if the 
outdoor unit does not receive a 
serial signal from one or more 
indoor unit for 30 seconds.
Compressor is stopped, if the 
outdoor unit does not receive a 
serial signal from all indoor units.
Compressor is stopped, and 
miswiring check operation ends. 
Thermistor 
short
Thermistor 
open
AC 
abnormal 
current
Serial signal 
error
Miswiring 
check error
When the room
is activated
turns ON and
the compressor
starts.
When the room 
turns ON 
and the 
compressor 
starts.
During 
compressor 
operation
During 
operation
During 
miswiring 
operation
Operation OFF
Operation OFF
Automatically 
restarts after safety 
time(90 seconds)
Automatically 
restarts as soon as 
the serial 
communication 
becomes possible.
Miswiring check 
operation will not
restart automatically.
1 time
Yes
Yes
1 time
Yes
Yes
8 times
Yes
Yes
No limit
Yes
Yes
8 times
Yes
Yes
13
Lowers the operating frequency if 
the temperature of any of indoor 
heat exchanger rises high 
temperature during heating. 
Stops the compressor if the 
temperature srays high for 1 minute
at minumum frequency.
Indoor heat
exchanger
overheat
prevention
control
During 
compressor 
operation
Automatically
restarts after
safety time.(90 sec.)
Automatically
restarts after
safety time.(90 sec.)
Automatically
restarts after
safety time.(90 sec.)
No limit
No
No
14
When a power factor module error
input is detected.
Power factor
module
(Active filter)
error
During 
compressor
operation
During 
compressor
operation
8 times
Yes
Yes
15
In the case that the feed back signal 
from the compressor is not input or
abnormal.
DC 
Compressor
rotation
error
8 times
Yes
Yes
NO. Function
Operation
Description
Detection time Restarts condition Restarts 
time
In
door
Out
door
Page of 2
Display