AE-XM18CR (serv.man16). Disassembly procedure - Sharp Air Conditioner Service Manual (repair manual). Page 9

Read Sharp AE-XM18CR (serv.man16) Service Manual online

67
AY-XM7/9/12CR
AY-XPM7/9/12CR
AE-XM18/24CR
DISASSEMBLING PROCEDURE FOR OUTDOOR UNIT
CAUTION: DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY SERVICING.
(The illustrations are for AE-XM24CR. Construction of AE-XM18CR may differ slightly from the illustration.)
2. Unscrew the 6 screws fixing the side cover R then
remove it
3. Unscrew the 7 screws fixing the cabinet then remove
it.
3 screws are at the left.
2 screws are at the right.
1 screw is at the front.
1 screw is at the rear.
4. Unscrew the 3 screws fixing the control box angle
then remove it.
CAUTION: DISCHARGE ELECTROLYTIC
CAPACITOR BEFORE TOUCHING THIS
CAPACITOR OR OTHER COMPONENTS
OR WIRINGS.
 5. Cut the 3 wire fixing bands.
6. Disconnect the 8 (AE-XM24CR) or 7 (AE-XM18CR)
connectors.
Expansion valve (CN12A,CN12B,CN12C) : 3pcs.
(AE-XM24CR)
Expansion valve (CN12A,CN12B) : 2pcs.
(AE-XM18CR)
Termistor (CN8A,CN8B) : 2pcs.
Fan motor (CN3) : 1pc.
Reverse valve coil (CN4) : 1pc
Display board unit (CN11) : 1pc
Note : Caution to connectors position especially the
expansion valves, when reinstalling
7. Remove the compressor cover B.
Disconnect 5 terminals.
Coil for PFC1 (L1) : 2pcs (White)
Compressor : 3pcs (Red, White and Orange)
Note : Caution to connectors position especially the
compressor, when reinstalling.
1. Unscrew the 3 screws fixing the control box cover
then remove it.