AE-M18 (serv.man2) - Sharp Air Conditioner Service Manual (repair manual). Page 13

Read Sharp AE-M18 (serv.man2) Service Manual online

13
AY-M09AE
AE-M18AE
FUNCTIONS
1. Temperature control characteristic
1-1
COOL operation
In the “COOL” mode, the thermostat circuit is
controlled by four thermostat lines (C1 thru C4).
1-3
HEAT operation
In the “HEAT” mode, the thermostat circuit
is controlled by six thermostat lines (H01 thru
H4).
Figure Y-1
1-2
DRY operation
In the “DRY” mode, the thermostat circuit is
controlled by three thermostat lines (D1 thru
D3).
Figure Y-3
2. Operation modes
The indoor fan motor is controlled in the indoor unit,
and the outdoor fan motor, compressor, and reverse
valve are controlled in the outdoor fan motor.
The operation mode of the outdoor unit is basically
decided by the indoor operation mode.
When the outdoor unit operation mode is heat, and the
indoor unit operation mode is cool or dry, or the outdoor
unit operation is heat, the Busy - LED in the indoor unit
flikers.  When the operation mode of the indoor
unit(called "A1", "A2") changes, the opeartion mode of
the outdoor unit changes in Table Y-1.
Figure Y-2
18
32
C1
C2
C3
C4
17.5
18.5
19.5
20.5
31.5
32.5
33.5
34.5
Preset temperature (˚C)
Room temperature (˚C)
Room temperature(˚C)
Preset temperature (˚C)
18
32
D1
D2
D3
17.5
18.5
19.5
31.5
32.5
33.5
Preset temperature (˚C)
H4
H3
H2
H1
H02
H01
17
19
21
22
24
26
31
33
35
36
38
40
18
32
Room temperature(˚C)
Page of 40