AE-A184 - Sharp Air Conditioner Specification (repair manual). Page 16

Read Sharp AE-A184 Specification online

16
AY-A184E
AY-A244E
AE-A184E
AE-A244E
19.Trouble suspension
When indoor fan motor is out of order or compressor-
lock occurs, the compressor, indoor fan motor, outdoor
fan motor, and louver are all stopped and the operation
LED(red) turns off and the timer LED(yellow) turns on
or off as follows.
In this case, when "ON/OFF" button in the remote
controller or "AUX" button in the unit is pushed, the
unit is out of "Trouble suspension".
Table Y-6 (AY-A184E)
ON
OFF
1sec.
1sec.
4sec.
Timer LED
(yellow)
Figure Y-15
Step 
10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
Output for outdoor unit 
Lamps
RED
YELLOW
Indoor
Fan motor
Louver
OFF 
Compressor 
Reverse Valve 
Ootdoor Fan Motor
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
(Back to step 1)
OFF 
OPEN 
ON 
D
OFF 
Flikering
OFF 
OFF 
ON 
ON 
CLOSE 
ON
ON 
OFF 
ON 
UL
OFF 
ON
ON 
OFF 
ON 
ON 
M
OFF 
ON 
ON 
OFF 
ON 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
ON 
OFF 
OFF 
ON 
OFF 
OFF 
OFF 
ON 
ON 
OFF 
OFF 
OFF
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
ON 
OFF 
OFF 
ON 
OFF 
OFF 
OFF 
OFF 
ON 
OFF 
OFF 
ON 
OFF 
OFF 
OFF 
OFF
OFF  
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
ON 
1
3
4
5
5
1
2
3
4
5
: 7˚C     Room temp.     42˚C                                                                            ON     
  7˚C     (Room temp.) or (Room temp.)     42˚C                                              OFF  
: –2˚C     Pipe temp.      42˚C                                                                           ON
  –2˚C     Pipe temp. or (Pipe temp.)      42˚C                                                  OFF
: 0.1V     (ANI2 INPUT VOLTAGE)    0.45V                                                     ON
  (0.1V     ANI2 INPUT VOLTAGE) or (ANI2 INPUT VOLTAGE)   0.45V         OFF
: When Power on start is effective, Timer LED(yellow) is OFF.
: When AUTO RESTART is effective, Operation LED(red) is OFF, and Timer LED(yellow) is ON.
Page of 44