Z8, Chassis - Panasonic TV Other Service Manuals (repair manual). Page 32

Read Panasonic Z8 / Chassis Other Service Manuals online

3DQDVRQLF
9.
Colour Output
The colour output stage receives the RGB signals
and provides processing for display on the CRT. This
is performed by the Triple Video Output IC IC351,
which is located on the Y-Board.
The Z8 chassis uses two variations.
TDA6107 is used on TVs with CRT’s below 25".
TDA6108 is used on 25" and 28" TVs and has an
increased bandwidth as well as being able to
withstand higher current.
Besides the differences mentioned above, both
devices are pin compatible and their basic operation
are identical.
9.1. Colour Output Stage
In order to avoid damage caused by long cathode
lines and thereby trim the frequency response, the
RGB output stage is mounted onto the CRT board.
The use of IC351 means that the number of
components are reduced to a minimum.
The RGB signals fed to the colour output stage are
driven from the UOC IC IC601, located on the
E-Board from pins 51, 52 and 53 via connectors E8
and Y2 pins 3, 2 and 1. The signals are fed directly to
IC351 pins 1(B), 2(G) and 3(R).
The RGB signals input to IC351 are amplified before
being output via pins 7(R), 8(G) and 9(B).
9.1.1. Cut-off Control Circuit
The leakage current and cut-off evaluation circuits of
UOC IC IC601 are used for the adjustment of the
output amplifiers, which are used to keep the picture
independent of ageing.
The cut-off control is a scan regulating circuit, which
electronically regulates for dynamic component
tolerances and the effects of wear and tear on the
picture tube etc.
It also offers the following advantages:
:
Automatic black level compensation
:
Prevention of colour purity errors during CRT
heating up time and stabilisation of excessive
ageing in the initial hours of operation.
During field flyback, the leakage current from the CRT
system is measured at ultra black before the RGB
cathode currents are measured. These measured
values are output at pin 5 of IC351 via connector Y2
pin 5, and applied to the UOC IC IC601 pin 50, located
on the E-Board.
The results of these measurements are then used in
the internal RGB processing and control stages of
IC601, compensating for CRT and component
degradation.
9.1.2. Switch-off Fluorescence Suppression
If the CRT is slow to discharge at switch-off, afterglow
flecks would occur. This is suppressed by transistor
Q351.
At switch on and during operation of the colour output
stage, C370 is charged. However, Q351 has no
effect, since the base of Q351 is more positive with
respect to its emitter so Q351 is non-conducting.
At switch-off, Q351 is switched On by the rapid
decrease of the supply line. Diode D373 becomes
reversed biased due to the charge held in capacitor
C370. This causes Q351 to become conductive so
C370 discharges via the emitter/collector junction of
Q351 and diodes D370, D371 and D372. This drives
the internal op-amps further and increases the output
of the op-amp, preventing afterglow. By the time the
capacitor C370 has discharged and the circuit
becomes inoperative, the CRT has discharged.
9.1.3. Beam Current Limiting
The CRT beam current is monitored from pin 3 of the
FBT T552, which works with virtual earthing. As the
beam current increases, an increasingly negative
charge is developed across capacitor C558. This
negative charge is fed to the BCL input of the UOC IC
IC601 pin 49 via resistors R628 and R624, where the
current level is monitored and compared to an internal
reference within the UOC IC. The result is used to
reduce the drive of the brightness and contrast
circuits.
However, If the beam current fails to be reduced, the
safety circuit is used to switch the TV off. If the beam
current reaches the maximum control range of the
FBT, the zener diode D403 conducts, causing diode
D603 to conduct. This negative charge is applied to
the base of transistor Q603, causing Q603 to switch
On. With the protection input pin 36 of the UOC IC
IC601 biased by resistors R2022 and R621, the
switching action of Q603 now increases the voltage
at pin 36 of IC601, switching this input High. After a
short delay the TV will be switched into standby.